POST error messages and beep codes

Page 121 highlights

Storage Enclosure: One or more fans have failed. Action: Replace the failed fan. Storage Enclosure: Warning: The enclosure is reporting a high temperature status. Action: Be sure that all fans are connected and operating properly. Replace any defective fans. For better airflow, remove any dust buildup from fans or other areas. If the problem persists, contact HP support ("Contacting HP" on page 185, "Contacting HP technical support or an authorized reseller" on page 185). Storage Enclosure: Warning: One or more redundant power supplies in this enclosure has failed or is not plugged in correctly. Action: Reseat the power supply firmly and check the power cable. If the problem persists, check the power supply. POST error messages and beep codes Introduction to POST error messages The error messages and codes in this section include all messages generated by ProLiant servers. Some messages are informational only and do not indicate any error. A server generates only the codes that are applicable to its configuration and options. HP ProLiant p-Class server blades do not have speakers and thus do not support audio output. Disregard the audible beeps information if the server falls into this category. IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server. WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components. Non-numeric messages or beeps only Advanced Memory Protection mode: Advanced ECC Audible Beeps: None Possible Cause: Advanced ECC support is enabled. Action: None. Advanced Memory Protection mode: Advanced ECC with hot-add support Audible Beeps: None Possible Cause: Advanced ECC with Hot-Add support is enabled. Action: None. Error messages 121

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201

Error messages 121
Storage Enclosure: One or more fans have failed.
Action:
Replace the failed fan.
Storage Enclosure: Warning: The enclosure is reporting a high temperature status.
Action:
Be sure that all
fans are connected and operating properly. Replace any defective fans. For better
airflow, remove any dust buildup from fans or other areas. If the problem persists, contact HP support
("
Contacting HP
" on page
185
, "
Contacting HP technical support or an authorized reseller
" on page
185
).
Storage Enclosure: Warning: One or more redundant power supplies in this
enclosure has failed or is not plugged in correctly.
Action:
Reseat the power supply firmly and check the power cable. If the problem persists, check the power
supply.
POST error messages and beep codes
Introduction to POST error messages
The error messages and codes in this section include all messages generated by ProLiant servers. Some
messages are informational only and do not indicate any error. A server generates only the codes that are
applicable to its configuration and options.
HP ProLiant p-Class server blades do not have speakers and thus do not support audio output. Disregard the
audible beeps information if the server falls into this category.
IMPORTANT:
This guide provides information for multiple servers. Some information may not
apply to the server you are troubleshooting. Refer to the server documentation for information on
procedures, hardware options, software tools, and operating systems supported by the server.
WARNING:
To avoid potential problems, ALWAYS read the warnings and cautionary
information in the server documentation before removing, replacing, reseating, or modifying
system components.
Non-numeric messages or beeps only
Advanced Memory Protection mode: Advanced ECC
Audible Beeps
: None
Possible Cause
: Advanced ECC support is enabled.
Action
: None.
Advanced Memory Protection mode: Advanced ECC with hot-add support
Audible Beeps
: None
Possible Cause
: Advanced ECC with Hot-Add support is enabled.
Action
: None.