HP ProLiant DL380 G3 with MSA500 HP ProLiant Servers Troubleshooting Guide - Page 171

Event list error messages

Page 171 highlights

1800 Series 1800-Slot X Drive Array - Array Accelerator Super-Cap is charging... ...The Array Accelerator Cache will be enabled once Super-Cap has been charged. No action is required. Audible Beeps: None Possible Cause: The Array Accelerator Super-Cap is charging. Action: No action is required. 1801-Slot X Drive Array - Please install Array Accelerator Super-Cap... ...The Array Accelerator Cache will be enabled once Super-Cap is installed and charged. Audible Beeps: None Possible Cause: The Array Accelerator Super-Cap needs to be installed. Action: Install the Array Accelerator Super-Cap. Event list error messages Introduction to event list error messages This section contains event list error messages recorded in the IML ("Integrated Management Log" on page 76), which can be viewed through different tools. The format of the list is different when viewed through different tools. An example of the format of an event as displayed on the IMD follows: **001 of 010** ---caution--03/19/2002 12:54 PM FAN INSERTED Main System Location: System Board Fan ID: 03 **END OF EVENT** WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components. IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server. NOTE: The error messages in this section may be worded slightly different than as displayed by the server. Error messages 171

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201

Error messages 171
1800 Series
1800-Slot X Drive Array - Array Accelerator Super-Cap is charging...
...The Array Accelerator Cache will be enabled once Super-Cap has been charged. No action is required.
Audible Beeps
: None
Possible Cause
: The Array Accelerator Super-Cap is charging.
Action
: No action is required.
1801-Slot X Drive Array - Please install Array Accelerator Super-Cap...
...The Array Accelerator Cache will be enabled once Super-Cap is installed and charged.
Audible Beeps
: None
Possible Cause
: The Array Accelerator Super-Cap needs to be installed.
Action
: Install the Array Accelerator Super-Cap.
Event list error messages
Introduction to event list error messages
This section contains event list error messages recorded in the IML ("
Integrated Management Log
" on page
76
), which can be viewed through different tools.
The format of the list is different when viewed through different tools. An example of the format of an event
as displayed on the IMD follows:
**001 of 010**
---caution---
03/19/2002
12:54 PM
FAN INSERTED
Main System
Location:
System Board
Fan ID: 03
**END OF EVENT**
WARNING:
To avoid potential problems, ALWAYS read the warnings and cautionary
information in the server documentation before removing, replacing, reseating, or modifying
system components.
IMPORTANT:
This guide provides information for multiple servers. Some information may not
apply to the server you are troubleshooting. Refer to the server documentation for information on
procedures, hardware options, software tools, and operating systems supported by the server.
NOTE:
The error messages in this section may be worded slightly different than as displayed by
the server.