HP ProLiant DL380 G3 with MSA500 HP ProLiant Servers Troubleshooting Guide - Page 170
disabled or the controller might not be usable until this problem is corrected.
View all HP ProLiant DL380 G3 with MSA500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 170 highlights
Audible Beeps: None Possible Cause: Power was interrupted while data was in the array accelerator memory, or the data stored in the array accelerator does not correspond to this drive array. Action: Match the array accelerator to the correct drive array, or run ACU to clear the data in the array accelerator. 1796-Slot X Drive Array - Array Accelerator Not Responding... ...Array Accelerator is temporarily disabled. Audible Beeps: None Possible Cause: Array accelerator is defective or is missing. Depending on the array controller model, the cache may be disabled or the controller might not be usable until this problem is corrected. Action: 1. Reseat the array accelerator daughter board if the connector is loose. 2. If the problem persists, replace the board. 1797-Slot X Drive Array - Array Accelerator Read Error Occurred... ...Data in Array Accelerator has been lost. Array Accelerator is disabled. Audible Beeps: None Possible Cause: Hard parity error detected while reading data from posted-writes memory. Action: Replace the array accelerator daughter board. 1798-Slot X Drive Array - Array Accelerator Self-Test Error Occurred... ...Array Accelerator is disabled. Audible Beeps: None Possible Cause: Array accelerator failed self-test. Depending on the array controller model, the cache may be disabled or the controller might not be usable until this problem is corrected. Action: Replace the array accelerator daughter board. 1799-Slot X Drive Array - Drive(s) Disabled due to Array Accelerator Data Loss... ...Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to re-enable logical drives. Audible Beeps: None Possible Cause: One or more logical drives failed due to loss of data in posted-writes memory. Action: • Press the F1 key to continue with the logical drives disabled. • Press the F2 key to accept data loss and re-enable logical drives. After pressing the F2 key, check the integrity of the file system and restore lost data from backup. Error messages 170
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
30
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52
-
53
-
54
-
55
-
56
-
57
-
58
-
59
-
60
-
61
-
62
-
63
-
64
-
65
-
66
-
67
-
68
-
69
-
70
-
71
-
72
-
73
-
74
-
75
-
76
-
77
-
78
-
79
-
80
-
81
-
82
-
83
-
84
-
85
-
86
-
87
-
88
-
89
-
90
-
91
-
92
-
93
-
94
-
95
-
96
-
97
-
98
-
99
-
100
-
101
-
102
-
103
-
104
-
105
-
106
-
107
-
108
-
109
-
110
-
111
-
112
-
113
-
114
-
115
-
116
-
117
-
118
-
119
-
120
-
121
-
122
-
123
-
124
-
125
-
126
-
127
-
128
-
129
-
130
-
131
-
132
-
133
-
134
-
135
-
136
-
137
-
138
-
139
-
140
-
141
-
142
-
143
-
144
-
145
-
146
-
147
-
148
-
149
-
150
-
151
-
152
-
153
-
154
-
155
-
156
-
157
-
158
-
159
-
160
-
161
-
162
-
163
-
164
-
165
-
166
-
167
-
168
-
169
-
170
-
171
-
172
-
173
-
174
-
175
-
176
-
177
-
178
-
179
-
180
-
181
-
182
-
183
-
184
-
185
-
186
-
187
-
188
-
189
-
190
-
191
-
192
-
193
-
194
-
195
-
196
-
197
-
198
-
199
-
200
-
201