HP ProLiant DL980 DL980 G7 Maintenance & Service Guide - Page 75
Advanced Options, Service Options, Serial Number, Enter, Product ID, The following warning appears
View all HP ProLiant DL980 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
To replace a system board: 1. Install the spare system board. 2. Replace all components removed from the failed system board. 3. Install the access panel. 4. Slide the server back into the rack. 5. Power up the server. After you replace the system board, you must re-enter the server serial number and the product ID. 1. During the server startup sequence, press the F9 key to access RBSU. 2. Select the Advanced Options menu. 3. Select Service Options. 4. Select Serial Number. The following warnings appear: WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NOT be modified. This option should only be used by qualified service personnel. This value should always match the serial number sticker located on the chassis. Warning: The serial number should ONLY be modified by qualified personnel. This value should always match the serial number located on the chassis. 5. Press the Enter key to clear the warning. 6. Enter the serial number and press the Enter key. 7. Select Product ID. The following warning appears: Warning: The Product ID should ONLY be modified by qualified personnel. This value should always match the Product ID on the chassis. 8. Enter the product ID and press the Enter key. 9. Press the Esc key to close the menu. 10. Press the Esc key to exit RBSU. 11. Press the F10 key to confirm exiting RBSU. The server automatically reboots. Illustrated parts catalog 75