HP Scitex FB500 HP Scitex FB500 and FB700 Printer Series - User Guide - Page 71
Re-install the lamp housings
View all HP Scitex FB500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
3. Install the spring-loaded clamp's dowels (A and B below) into the reflector. Figure 9-9 Installing the dowels into the reflector 4. Repeat this procedure for the other lamp. Re-install the lamp housings Re-install the user-end lamp housing 1. Secure the lamp housing to the lamp assembly using the original two lower silver screws on the user end of the carriage (see screws A in Figure 9-3 User end screws on page 61 for locations). ● If you have difficultly fitting the lamp housing back onto the lamp base, loosen the four screws indicated below. ● If the lamp housing is still difficult to install, squeeze the side of the lamp base to bend the side in about 0.8 mm (0.031 in). Figure 9-10 Loosening screws to ease installation ENWW Replace UV lamp bulb (500-1000 hours) 65