HP StoreOnce D2D4324 HP StoreOnce Backup System CLI Reference Guide (BB877-909 - Page 156

Requirements for Command Execution, Successful Command Output, Command Operation during Abnormal Conditions, Examples

Page 156 highlights

Requirements for Command Execution • The command entry must conform to the command syntax. • All object values must be valid; see the object descriptions for details. • All parameter values must be valid; see the parameter descriptions for details. Successful Command Output Upon successful completion of the command, the following is displayed: Command Successful Command Operation during Abnormal Conditions If any of the command execution requirements fail, command execution terminates. The cartridge is not added to the library and one of these error messages is displayed: • Command Failed - the command does not conform to the correct command syntax "vtl create cartridge [SETX ] LIBX { ALL | slot | mail } [WriteProtect { yes | no}] [barcode ] [CartSize {10 | 25 | 50 | 100 | 200 | 400 | 800 | 1000 | 1200 | 1400 | 1600 | 3200}]" • Command Failed - The service set is invalid • Command Failed - The service set does not exist • Command Failed - The library is invalid • Command Failed - The library does not exist • Command Failed - "ALL" slot or a mail must be defined • Command Failed - The slot does not exist in library • Command Failed - The mail slot does not exist in library • Command Failed - The slot is not empty • Command Failed - The mail slot is not empty • Command Failed - The barcode string does not conform to the library barcode parameters • Command Failed - The barcode string must consist of 8 alphanumeric characters • Command Failed - The cartridge size must be 10, 25, 50, 100, 200, 400, 800, 1000, 1200, 1400, 1600 or 3200 Examples # vtl create cartridge SET1 LIB1 ALL Command Successful # vtl create cartridge LIB1 slot 2 Command Successful 156 Alphabetical List of Commands and Details

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

Requirements for Command Execution
The command entry must conform to the command syntax.
All object values must be valid; see the object descriptions for details.
All parameter values must be valid; see the parameter descriptions for details.
Successful Command Output
Upon successful completion of the command, the following is displayed:
Command Successful
Command Operation during Abnormal Conditions
If any of the command execution requirements fail, command execution terminates. The cartridge
is not added to the library and one of these error messages is displayed:
Command Failed - the command does not conform to the correct command
syntax
vtl create cartridge [SETX ] LIBX { ALL | slot <number> |
mail <number> } [WriteProtect { yes | no}] [barcode <string>]
[CartSize {10 | 25 | 50 | 100 | 200 | 400 | 800 | 1000 | 1200 | 1400
| 1600 | 3200}]
Command Failed
The service set <SETX> is invalid
Command Failed
The service set <SETX> does not exist
Command Failed
The library <LIBX> is invalid
Command Failed
The library <LIBX> does not exist
Command Failed
ALL
slot or a mail must be defined
Command Failed
The slot <slot> does not exist in library
Command Failed
The mail slot <mail> does not exist in library
Command Failed
The slot <slot> is not empty
Command Failed
The mail slot <mail> is not empty
Command Failed
The barcode string does not conform to the library
barcode parameters
Command Failed
The barcode string must consist of 8 alphanumeric
characters
Command Failed
The cartridge size must be 10, 25, 50, 100, 200,
400, 800, 1000, 1200, 1400, 1600 or 3200
Examples
# vtl create cartridge SET1 LIB1 ALL
Command Successful
# vtl create cartridge LIB1 slot 2
Command Successful
156
Alphabetical List of Commands and Details