HP StoreOnce D2D4324 HP StoreOnce Backup System CLI Reference Guide (BB877-909 - Page 50
hardware show status, All parameter values must be valid; see the parameter descriptions for details.
![]() |
View all HP StoreOnce D2D4324 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
hardware show status Description of Command Function Provides status on all the hardware components of the StoreOnce system. Command Syntax hardware show status [detail] [dev-id] Command Authority Operator and Administrator Command Object Requirements Not applicable - no objects exist within this command. Command Parameter Requirements • detail - This optional parameter provides a detailed output for the hardware components selected. If not defined, only the device ID and its status are provided. • dev-id - This optional parameter selects a particular device and its immediate children to have their statuses shown. If not defined, the top level status and device IDs of couplets (with their nodes and storage arrays) and internal network switches are shown. The device ID of any component can be found using the hardware show status command and then using that device ID with the same command to view the device IDs of its subcomponents. Requirements for Command Execution • The command entry must conform to the command syntax. • All parameter values must be valid; see the parameter descriptions for details. Successful Command Output Upon successful completion of the command, the status of the selected devices is shown. NOTE: If CLI paging is enabled, the output of this command is displayed with paging. Command Operation during Abnormal Conditions If any of the command execution requirements fail, command execution terminates. The hardware status is not displayed and one of these error messages is displayed: • Command Failed - the command does not conform to the required syntax, SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this section. • Command Failed - Component for the device ID does not exist in system Examples > hardware show status dev-id StatusText Couplet_1 down - msa1 warn - msa2 warn - hp85647867b2-2 up - hp85647867b2-1 up switch1 up switch2 up Command Successful > hardware show status msa1 dev-id msa1 - controller-1-1 StatusText ---------warn up 50 Alphabetical List of Commands and Details
![](/manual_guide/products/hewlettpackard-d2d2502i-hp-storeonce-backup-cli-reference-guide-bb87790906-2013-b3556cc/50.png)