HP StoreOnce D2D4324 HP StoreOnce Backup System CLI Reference Guide (BB877-909 - Page 38

hardware poweroff, Upon successfully sending the power off request, the following is displayed

Page 38 highlights

hardware poweroff NOTE: This command applies to multi-node products only. Description of Command Function Powers down the StoreOnce appliance. If a file server node is defined in the command entry, only this node is powered down. NOTE: This command will only work if failover is enabled. See the system enable failover command, "system enable failover" (page 125) Command Syntax hardware poweroff [NODEX] Command Authority Administrator Command Object Requirements NODEX - As an option, this can be used to define an individual file server node. X is a unique numeric index. NODEX is a label uniquely defining the hardware component; it was assigned during the initial automatic hardware initialization and configuration and its value resides in the "node_config" file. A complete list of the NODEX labels can be obtained using the hardware show node status command (see "hardware show node status" (page 48)). If a file server node is defined, only this node is powered down. Command Parameter Requirements Not applicable - no parameters exist within this command. Requirements for Command Execution • The command entry must conform to the command syntax. • At least one system with an active CLI must exist. • If a file serving node is defined in the command entry, the defined node must be powered up. • This command will only work if failover is enabled. Successful Command Output Upon successfully sending the power off request, the following is displayed: poweroff request successfully sent NOTE: This message only indicates the success for the shutdown request. The hardware show node status command (see "hardware show node status" (page 48)) must be entered to verify the server nodes shutdown correctly. Also, if the shutdown applies to the node currently supporting the CLI interface, the session will be terminated following this command. Command Operation during Abnormal Conditions • If the command does not conform to the required syntax, the following is displayed: Command Failed - the command does not conform to the required syntax, SYNTAX where SYNTAX is the command syntax as described under Command Syntax in this section. • If the node is already powered down, the following is displayed: Command Failed - NODEX already shutdown, where NODEX is the file server node object defined in the command entry. Example # hardware poweroff node1 38 Alphabetical List of Commands and Details

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

hardware poweroff
NOTE:
This command applies to multi-node products only.
Description of Command Function
Powers down the StoreOnce appliance. If a file server node is defined in the command entry, only
this node is powered down.
NOTE:
This command will only work if failover is enabled. See the
system enable failover
command,
“system enable failover” (page 125)
Command Syntax
hardware poweroff [NODEX]
Command Authority
Administrator
Command Object Requirements
NODE
X
– As an option, this can be used to define an individual file server node. X is a unique
numeric index. NODE
X
is a label uniquely defining the hardware component; it was assigned
during the initial automatic hardware initialization and configuration and its value resides in the
“node_config” file. A complete list of the NODE
X
labels can be obtained using the
hardware
show node status
command (see
“hardware show node status” (page 48)
). If a file server
node is defined, only this node is powered down.
Command Parameter Requirements
Not applicable – no parameters exist within this command.
Requirements for Command Execution
The command entry must conform to the command syntax.
At least one system with an active CLI must exist.
If a file serving node is defined in the command entry, the defined node must be powered up.
This command will only work if failover is enabled.
Successful Command Output
Upon successfully sending the power off request, the following is displayed:
poweroff request successfully sent
NOTE:
This message only indicates the success for the shutdown request. The
hardware show
node status
command (see
“hardware show node status” (page 48)
) must be entered to verify
the server nodes shutdown correctly. Also, if the shutdown applies to the node currently supporting
the CLI interface, the session will be terminated following this command.
Command Operation during Abnormal Conditions
If the command does not conform to the required syntax, the following is displayed:
Command Failed - the command does not conform to the required syntax,
SYNTAX
where SYNTAX is the command syntax as described under Command Syntax in this
section.
If the node is already powered down, the following is displayed:
Command Failed
NODEX already shutdown
, where NODE
X
is the file server node
object defined in the command entry.
Example
# hardware poweroff node1
38