HP StoreOnce D2D4324 HP StoreOnce Backup System CLI Reference Guide (BB877-909 - Page 81
StoreOnce B6200 Backup System Installation Planning and Preparation Guide and Checklists
![]() |
View all HP StoreOnce D2D4324 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
StoreOnce B6200 Backup System Installation Planning and Preparation Guide and Checklists for more detailed information about supported bonding modes. Bonding mode Description Default Bonding Mode for: Mode 1 (Active/Backup) Simple bonding mode that allows network traffic via one active Templates 1, 3, 4, and 5 port only. If the active network fails then traffic moves to the backup port. Mode 4 (IEEE 802.3ad Dynamic Link Aggregation) LACP bonding mode that requires a special external switch configuration. Provides a link aggregation solution which increases the bond physical bandwidth. none Mode 6 (Active Load balance solution that can be used in a 2-switch Load Balancing) configuration. The switch must allow ARP negotiation (but no specific external switch configuration is required). Template 2 IMPORTANT: If a parameter is undefined in the modify command sequence, the current parameter value remains unchanged. If a parameter is given the value "undefined," a value is no longer declared for the parameter. Requirements for Command Execution • The command entry must conform to the command syntax. • All object values must be valid; see the object descriptions for details. • All parameter values must be valid; see the parameter descriptions for details. Successful Command Output Upon successful completion of the command, information on the external network configuration is displayed. Command Operation during Abnormal Conditions If the command does not conform to the required syntax, the following is displayed: Command Failed - the command does not conform to the required syntax, SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this section. Examples Example 1 modifies an existing named network configuration: net modify subnet save1 Subnet2 ipaddr 1.2.3.4 gateway 5.6.7.8 netmask 255.255.0.0 domain gbr.hp.com default yes bonding 5 port eth0,eth2 netmask 255.255.255.0 Additional examples: # net add subnet management subnet 10GbE ipaddr dchp ports 4,5 #net modify subnet management 10GbE gateway 13.25.25.1 net modify subnet 81
![](/manual_guide/products/hewlettpackard-d2d2502i-hp-storeonce-backup-cli-reference-guide-bb87790906-2013-b3556cc/81.png)