HP StoreOnce D2D4324 HP StoreOnce Backup System CLI Reference Guide (BB877-909 - Page 163

Command Operation during Abnormal Conditions, Example, the command is terminated and the CLI

Page 163 highlights

Command Operation during Abnormal Conditions • If any of the command execution requirements fail, command execution terminates. The cartridge is not deleted from the library and one of these error messages is displayed: ◦ Command Failed - Did not conform to the correct command syntax "vtl delete cartridge [SETX] LIBX [{CARTX | ALL}] [barcode ] [mail ] [slot ]" ◦ Command Failed - The service set is invalid ◦ Command Failed - The service set does not exist ◦ Command Failed - The library is invalid ◦ Command Failed - The library does not exist ◦ Command Failed - The cartridge(s) to be deleted was not defined ◦ Command Failed - The cartridge does not exist ◦ Command Failed - The mail slot does not exist in the library ◦ Command Failed - The slot does not exist in the library ◦ Command Failed - The mail slot does not contain a cartridge ◦ Command Failed - The slot does not contain a cartridge ◦ Command Failed - The barcode is invalid ◦ Command Failed - The barcode string must consist of 8 alphanumeric characters ◦ Command Failed - A cartridge with barcode does not exist in the library • If you do not respond to the warning message with y, the command is terminated and the CLI returns to the user prompt. Example # vtl delete cartridge LIB1 slot 3 Command Successful vtl delete cartridge 163

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

Command Operation during Abnormal Conditions
If any of the command execution requirements fail, command execution terminates. The
cartridge is not deleted from the library and one of these error messages is displayed:
Command Failed
Did not conform to the correct command syntax
vtl delete cartridge [SETX] LIBX [{CARTX | ALL}] [barcode
<string>] [mail <number>] [slot <number>]
Command Failed
The service set <SETX> is invalid
Command Failed
The service set <SETX> does not exist
Command Failed
The library <LIBX> is invalid
Command Failed
The library <LIBX> does not exist
Command Failed
The cartridge(s) to be deleted was not defined
Command Failed
The cartridge <CARTX> does not exist
Command Failed
The mail slot <mail> does not exist in the
library
Command Failed
The slot <slot> does not exist in the library
Command Failed
The mail slot <mail> does not contain a cartridge
Command Failed
The slot <slot> does not contain a cartridge
Command Failed
The barcode is invalid
Command Failed
The barcode string must consist of 8 alphanumeric
characters
Command Failed
A cartridge with barcode <barcode> does not
exist in the library
If you do not respond to the warning message with
y
, the command is terminated and the CLI
returns to the user prompt.
Example
# vtl delete cartridge LIB1 slot 3
Command Successful
vtl delete cartridge
163