HP StoreOnce D2D4324 HP StoreOnce Backup System CLI Reference Guide (BB877-909 - Page 40

hardware powerup, Upon successfully sending the power up request, the following is displayed

Page 40 highlights

hardware powerup NOTE: This command applies to multi-node products only. Description of Command Function Powers up the StoreOnce appliance. If a file server node is defined in the command entry, only this node is powered up. Command Syntax hardware powerup [NODEX] Command Authority Administrator Command Object Requirements NODEX - As an option, this can be used to define an individual file server node. X is a unique numeric index. NODEX is a label uniquely defining the hardware component; it was assigned during the initial automatic hardware initialization and configuration and its value resides in the "node_config" file. A complete list of the NODEX labels can be obtained using the hardware show node status command (see "hardware show node status" (page 48)). If a file server node is defined, only this node is powered up. Command Parameter Requirements Not applicable - no parameters exist within this command. Requirements for Command Execution • The command entry must conform to the command syntax. • At least one system with an active CLI must exist. • If a file serving node is defined in the command entry, the defined node must be powered up. Successful Command Output Upon successfully sending the power up request, the following is displayed: power up request successfully sent NOTE: This message only indicates the success for the power up request. The hardware show node status command (see "hardware show node status" (page 48)) must be entered to verify that the server nodes powered up correctly. Command Operation during Abnormal Conditions • If the command does not conform to the required syntax, the following is displayed: Command Failed - the command does not conform to the required syntax, SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this section. • If the entire StoreOnce appliance or the specified node is already powered up, the following is displayed: Command Failed - device already powered up Example # hardware powerup node1 power up request successfully sent 40 Alphabetical List of Commands and Details

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

hardware powerup
NOTE:
This command applies to multi-node products only.
Description of Command Function
Powers up the StoreOnce appliance. If a file server node is defined in the command entry, only
this node is powered up.
Command Syntax
hardware powerup [NODEX]
Command Authority
Administrator
Command Object Requirements
NODE
X
– As an option, this can be used to define an individual file server node. X is a unique
numeric index. NODE
X
is a label uniquely defining the hardware component; it was assigned
during the initial automatic hardware initialization and configuration and its value resides in the
“node_config” file. A complete list of the NODE
X
labels can be obtained using the
hardware
show node status
command (see
“hardware show node status” (page 48)
). If a file server
node is defined, only this node is powered up.
Command Parameter Requirements
Not applicable – no parameters exist within this command.
Requirements for Command Execution
The command entry must conform to the command syntax.
At least one system with an active CLI must exist.
If a file serving node is defined in the command entry, the defined node must be powered up.
Successful Command Output
Upon successfully sending the power up request, the following is displayed:
power up request successfully sent
NOTE:
This message only indicates the success for the power up request. The
hardware show
node status
command (see
“hardware show node status” (page 48)
) must be entered to verify
that the server nodes powered up correctly.
Command Operation during Abnormal Conditions
If the command does not conform to the required syntax, the following is displayed:
Command Failed - the command does not conform to the required syntax,
SYNTAX
, where SYNTAX is the command syntax as described under Command Syntax in this
section.
If the entire StoreOnce appliance or the specified node is already powered up, the following
is displayed:
Command Failed
device already powered up
Example
# hardware powerup node1
power up request successfully sent
40
Alphabetical List of Commands and Details