IBM 8658 User Guide - Page 141

connection.

Page 141 highlights

Error Code/Symptom FRU/Action 020-XXX-000 (Failed PCI Interface 1. System Board test) 020-XXX-001 (Failed Hot-Swap Slot 1 PCI Latch test) 1. PCI Hot-Swap Latch Assembly 2. System Board 020-XXX-002 (Failed Hot-Swap Slot 2 PCI Latch test) 1. PCI Hot-Swap Latch Assembly 2. System Board 020-XXX-003 (Failed Hot-Swap Slot 3 PCI Latch test) 1. PCI Hot-Swap Latch Assembly 2. System Board 020-XXX-004 (Failed Hot-Swap Slot 4 PCI Latch test) 1. PCI Hot-Swap Latch Assembly 2. System Board 030-XXX-000 (Failed Internal SCSI 1. System Board interface test) 030-XXX-00N (Failed SCSI test on 1. Adapter PCI slot N. Check system error log before replacing a FRU.) 035-XXX-099 1. No adapters were found. 2. If adapter is installed re-check connection. 035-XXX-S99 (Failed RAID test on 1. Cable PCI slot S. Check System Error Log before replacing a FRU.) 2. SCSI Backplane 3. Adapter 035-XXX-SNN (Check System 1. Fixed Disk with SCSI ID NN on RAID adapter in Error Log before replacing a FRU. PCI slot S. NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. SCSI Backplane 4. Adapter 075-XXX-000 (Failed Power Supply test) 1. Power Supply 089-XXX-001 (Failed Microprocessor test) 1. VRM 1 2. Microprocessor 1 089-XXX-002 (Failed Optional Microprocessor test) 1. VRM 2 2. Microprocessor 2 165-XXX-000 (Failed Service Processor test) 1. System Board. Before replacing the System Board, ensure that System Board jumper J45 is not installed (the default) when the error occurs. 2. Power Backplane 3. Hot-Swap Drive Backplane 180-XXX-000 (Diagnostics LED failure) 1. Run Diagnostic LED test for the failing LED. 2. Power Switch Assembly Symptom-to-FRU index 131

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

Error
Code/Symptom
FRU/Action
020-XXX-000
(Failed
PCI
Interface
test)
1.
System
Board
020-XXX-001
(Failed
Hot-Swap
Slot
1
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
Assembly
2.
System
Board
020-XXX-002
(Failed
Hot-Swap
Slot
2
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
Assembly
2.
System
Board
020-XXX-003
(Failed
Hot-Swap
Slot
3
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
Assembly
2.
System
Board
020-XXX-004
(Failed
Hot-Swap
Slot
4
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
Assembly
2.
System
Board
030-XXX-000
(Failed
Internal
SCSI
interface
test)
1.
System
Board
030-XXX-00N
(Failed
SCSI
test
on
PCI
slot
N.
Check
system
error
log
before
replacing
a
FRU.)
1.
Adapter
035-XXX-099
1.
No
adapters
were
found.
2.
If
adapter
is
installed
re-check
connection.
035-XXX-S99
(Failed
RAID
test
on
PCI
slot
S.
Check
System
Error
Log
before
replacing
a
FRU.)
1.
Cable
2.
SCSI
Backplane
3.
Adapter
035-XXX-SNN
(Check
System
Error
Log
before
replacing
a
FRU.
NN
=
SCSI
ID
of
failing
fixed
disk.)
1.
Fixed
Disk
with
SCSI
ID
NN
on
RAID
adapter
in
PCI
slot
S.
035-253-S99
(RAID
adapter
initialization
failure)
1.
ServeRAID
Adapter
in
slot
S
is
not
configured
properly.
Obtain
the
basic
and
extended
configuration
status
and
refer
to
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Cable
3.
SCSI
Backplane
4.
Adapter
075-XXX-000
(Failed
Power
Supply
test)
1.
Power
Supply
089-XXX-001
(Failed
Microprocessor
test)
1.
VRM
1
2.
Microprocessor
1
089-XXX-002
(Failed
Optional
Microprocessor
test)
1.
VRM
2
2.
Microprocessor
2
165-XXX-000
(Failed
Service
Processor
test)
1.
System
Board.
Before
replacing
the
System
Board,
ensure
that
System
Board
jumper
J45
is
not
installed
(the
default)
when
the
error
occurs.
2.
Power
Backplane
3.
Hot-Swap
Drive
Backplane
180-XXX-000
(Diagnostics
LED
failure)
1.
Run
Diagnostic
LED
test
for
the
failing
LED.
2.
Power
Switch
Assembly
Symptom-to-FRU
index