Page 152 highlights
Message Action System over temperature for 1. Ensure system is being properly cooled; see CPU ″X″ (level-warning; CPU ″X″ "Temperature checkout" on page 28. reporting over temperature condition) System under recommended CPU ″X″ temperature (level-warning; system reporting under temperature condition for CPU ″X″) 1. Ambient temperature must be within normal operating specifications; (see "Features and specifications" on page 3. Fan error messages Message Action Fan ″X″ failure (level-critical; fan ″X″ had a failure) 1. Check connections to fan ″X″ 2. Replace fan ″X″ Fan ″X″ fault (level-critical; fan ″X″ 1. Check connections to fan ″X″ beyond recommended RPM range) 2. Replace fan ″X″ Power error messages Message Power supply ″X″ current fault (level-critical; excessive current demand on power supply ″X″) Power supply ″X″ DC good fault (level-critical; power good signal not detected for power supply ″X″) Power supply ″X″ fan fault (level-critical; fan fault in power supply ″X″) Power supply ″X″ fault (level-critical; overcurrent condition exists) Power supply ″X″ 12V fault (level-critical; overcurrent condition detected) Power supply ″X″ 3.3V fault (level-critical; 3.3V power supply ″X″ had an error) Power supply ″X″ 5V fault (level-critical; 5V power supply ″X″ had an error) System over recommended ″X″ current (level-non-critical; system running too much current on that voltage) Action 1. See "Power checkout" on page 26. 1. Replace power supply ″X″ 1. Replace power supply ″X″ 1. See "Power checkout" on page 26. 1. See "Power checkout" on page 26. 1. See "Power checkout" on page 26. 1. See "Power checkout" on page 26. 1. See "Power checkout" on page 26. 142 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
![](/manual_guide/products/ibm-8658-user-guide-f978985/152.png)