2 Primary microprocessor failure (CR1) 3 Voltage regulator module (VRM2) failure (CR16) 4 Integrated voltage regulator (VRM1) failure (CR4) 5 Diagnostics panel 6 Advanced System Management Processor error (CR70) 7 Power-on (CR56) 8 DIMM1 failure (CR23) 9 DIMM2 failure (CR28) 10 DIMM3 failure (CR18) 11 DIMM4 failure (CR20) Table 9. Diagnostics panel LEDs LED Description PS1 Power supply 1 failure. PS2 Power supply 2 failure. PS3 Power supply 3 failure. NON Non-redundant power. OVER Overspecification. The system has exceeded the power capabilities of the installed power supply units. NMI Non-maskable-interrupt occurred. TEMP System temperature exceeded maximum rating. FAN A fan failed or is operating slowly. MEM CPU Memory failure. One or more memory DIMMS have failed. Microprocessor failure. One or both microprocessors have failed. PCI 1 Error on primary PCI channel (A) or system board. PCI 2 Error on secondary PCI channel (B) or system board. VRM Error on voltage regulator module or on integrated voltage regulator. DASD1 The hot-swap disk drive backplane on SCSI channel A has failed. DASD2 Not used. Before you begin Before you begin to install options in your server, read the following information: v Become familiar with the safety and handling guidelines specified under "Working inside a server with power on" on page 47, "Handling static sensitive devices" on page 47, and read "Safety information" on page 152. These guidelines will help you work safely while working with your server or options. v You do not need to turn off the server to install or replace hot-swap power supplies, or hot-swap drives. v The orange color on components and labels in your server indicates hot-swap components. This means that you can install or remove the component while the system is running, provided that your system is configured to support this function. For complete details about installing or removing a hot-swap component, see the information provided in this chapter. 46 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

±2²
Primary
microprocessor
failure
(CR1)
±3²
Voltage
regulator
module
(VRM2)
failure
(CR16)
±4²
Integrated
voltage
regulator
(VRM1)
failure
(CR4)
±5²
Diagnostics
panel
±6²
Advanced
System
Management
Processor
error
(CR70)
±7²
Power-on
(CR56)
±8²
DIMM1
failure
(CR23)
±9²
DIMM2
failure
(CR28)
±10²
DIMM3
failure
(CR18)
±11²
DIMM4
failure
(CR20)
Table
9.
Diagnostics
panel
LEDs
LED
Description
PS1
Power
supply
1
failure.
PS2
Power
supply
2
failure.
PS3
Power
supply
3
failure.
NON
Non-redundant
power.
OVER
Overspecification.
The
system
has
exceeded
the
power
capabilities
of
the
installed
power
supply
units.
NMI
Non-maskable-interrupt
occurred.
TEMP
System
temperature
exceeded
maximum
rating.
FAN
A
fan
failed
or
is
operating
slowly.
MEM
Memory
failure.
One
or
more
memory
DIMMS
have
failed.
CPU
Microprocessor
failure.
One
or
both
microprocessors
have
failed.
PCI
1
Error
on
primary
PCI
channel
(A)
or
system
board.
PCI
2
Error
on
secondary
PCI
channel
(B)
or
system
board.
VRM
Error
on
voltage
regulator
module
or
on
integrated
voltage
regulator.
DASD1
The
hot-swap
disk
drive
backplane
on
SCSI
channel
A
has
failed.
DASD2
Not
used.
Before
you
begin
Before
you
begin
to
install
options
in
your
server,
read
the
following
information:
v
Become
familiar
with
the
safety
and
handling
guidelines
specified
under
“Working
inside
a
server
with
power
on”
on
page
47,
“Handling
static
sensitive
devices”
on
page
47,
and
read
“Safety
information”
on
page
152.
These
guidelines
will
help
you
work
safely
while
working
with
your
server
or
options.
v
You
do
not
need
to
turn
off
the
server
to
install
or
replace
hot-swap
power
supplies,
or
hot-swap
drives.
v
The
orange
color
on
components
and
labels
in
your
server
indicates
hot-swap
components.
This
means
that
you
can
install
or
remove
the
component
while
the
system
is
running,
provided
that
your
system
is
configured
to
support
this
function.
For
complete
details
about
installing
or
removing
a
hot-swap
component,
see
the
information
provided
in
this
chapter.
46
:
Netfinity
5100
Type
8658
Models
11Y,
21Y,
31Y,
41Y,
51Y,
1RY,
2RY,
3RY,
4RY,
5RY