Time-out, Value, Output parameters to the device, Sector Count
View all IBM IC35L020 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Output parameters to the device Sector Count Time-out Parameter. If it is zero, the automatic power down sequence is disabled. If it is non-zero, then the automatic power down sequence is enabled. The time-out interval is shown below: Value ------- 0 1-240 241-251 252 253 254 255 Time-out Timer disabled Value * 5 seconds (Value-240) * 30 minutes 21 minutes 8 hours 21 minutes 10 seconds 21 minutes 15 seconds When the automatic power down sequence is enabled, the drive will enter Standby mode automatically if the time-out interval expires with no drive access from the host. The time-out interval will be reinitialized if there is a drive access before the time-out interval expires. Deskstar 60 GXP Hard disk drive specification 119
Output parameters to the device
Sector Count
Time-out Parameter. If it is zero, the automatic power down sequence is
disabled. If it is non-zero, then the automatic power down sequence is enabled.
The time-out interval is shown below:
21 minutes 15 seconds
255
21 minutes 10 seconds
254
8 hours
253
21 minutes
252
(Value-240) * 30 minutes
241-251
Value * 5 seconds
1-240
Timer disabled
0
------------------------
-------
Time-out
Value
When the automatic power down sequence is enabled, the drive will enter Standby mode automatically if
the time-out interval expires with no drive access from the host. The time-out interval will be reinitialized if
there is a drive access before the time-out interval expires.
Deskstar
60 GXP Hard disk drive specification