IBM IC35L020 Hard Drive Specifications - Page 189

Standby E2h/96h

Page 189 highlights

15.33 Standby (E2h/96h) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature Sector Count V V V V V V V V Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D - - - - Command 1 1 1 0 0 0 1 0 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status see below Error Register 76543210 CRC UNC 0 IDN 0 ABT T0N AMN 00000V00 Status Register 7 6 5 4 3 2 10 BSY RDY DF DSC DRQ COR IDX ERR 0 V 0 V - 0 -V Figure 133. Standby Command (E2h/96h) The Standby command causes the device to enter the Standby Mode immediately and to set the auto power down time-out parameter (standby timer). When the Standby mode is entered, the drive is spun down but the interface remains active. If the drive is already spun down, the spin down sequence is not executed. During the Standby mode the drive will respond to commands but there is a delay while waiting for the spindle to reach operating speed. The automatic power down sequence is enabled and the timer starts counting down when the drive returns to Idle mode. Deskstar 60 GXP Hard disk drive specification 175

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209

15.33 Standby (E2h/96h)
see below
Status
1 1 1 0 0 0 1 0
Command
- - - - - - - -
Device/Head
1 - 1 D - - - -
Device/Head
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder High
- - - - - - - -
Cylinder Low
- - - - - - - -
Cylinder Low
- - - - - - - -
Sector Number
- - - - - - - -
Sector Number
- - - - - - - -
Sector Count
V V V V V V V V
Sector Count
see below
Error
- - - - - - - -
Feature
- - - - - - - -
Data
- - - - - - - -
Data
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Register
Command Block Input
Registers
Command Block Output
Registers
V
0
V
0
V
0
0
0
V
0
0
0
0
0
ERR
IDX
COR
DRQ
DSC
DF
RDY
BSY
AMN
T0N
ABT
0
IDN
0
UNC
CRC
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Status Register
Error Register
Figure 133. Standby Command (E2h/96h)
The Standby command causes the device to enter the Standby Mode immediately and to set the auto
power down time-out parameter (standby timer).
When the Standby mode is entered, the drive is spun down but the interface remains active. If the drive is
already spun down, the spin down sequence is not executed.
During the Standby mode the drive will respond to commands but there is a delay while waiting for the
spindle to reach operating speed.
The automatic power down sequence is enabled and the timer starts counting down when the drive
returns to Idle mode.
Deskstar
60 GXP Hard disk drive specification
175