IBM IC35L020 Hard Drive Specifications - Page 61
Environment, 2.1 Temperature and humidity
View all IBM IC35L020 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
9.2 Environment 9.2.1 Temperature and humidity Operating conditions Temperature Relative humidity Maximum wet bulb temperature Maximum temperature gradient Altitude Shipping conditions Temperature Relative humidity Maximum wet bulb temperature Altitude Storage conditions Temperature Relative humidity Maximum wet bulb temperature Altitude 5 to 55°C1 8 to 90% non-condensing 29.4°C non-condensing 15°C/Hour -300 to 3,048 m -40 to 65°C 5 to 95% non-condensing 35°C non-condensing -300 to 12,000 m 0 to 65°C 5 to 95% non-condensing 35°C non-condensing -300 to 12,000 m 1The system is responsible for providing sufficient air movement to maintain a surface temperature below 60°C at the center of the top cover of the drive. Figure 43. Operation, shipping, and storage temperature and humidity requirements table Relative Humidity (%) 100 90 80 70 31°C/90% 36°C/95% Wet Bulb 35°C Wet Bulb 29.4°C 60 Shipping/Storage 50 Operating 40 30 20 65°C/14% 55°C/15% 10 0 -40 -20 0 20 40 60 Temperature (°C) DERA005.prz Figure 44. Environmental specifications-operation, shipping, storage temperature, and humidity requirements Deskstar 60 GXP Hard disk drive specification 47