Icom IC-2300H Instruction Manual - Page 39

■ Scan edges programming, DIAL], FUNC]

Page 39 highlights

7 SCAN OPERATION ■ Scan edges programming Scan edges can be programmed in the same manner as memory channels. Scan edges are programmed into scan edges, 1A/1b to 3A/3b, in memory channel sheet. q Set the desired edge frequency in the VFO mode: w Push [MW] (S.MW). • The " " icon and channel number blink. e Rotate [DIAL] to select one of scan edge channels, 1A, 2A or 3A. r Hold down [MW] (S.MW) for 1 second to store it. • 3 beeps sound and the transceiver automatically returns to the VFO mode. • Scan edge 1b, 2b or 3b is automatically selected when continuing to hold down [MW] (S.MW) after programming. t T o program a frequency for the other pair of scan edges, the 1b, 2b or 3b, repeat steps q through r. • If the same frequency is programmed into a pair of scan edges, the programmed scan cannot start. Using the HM-133V z Set the desired frequency in the VFO mode. x Push [FUNC] , and then [MW] . c Push [Y] or [Z] to select the scan edge channels, 1A, 2A or 3A. v Push [FUNC] , and then hold down [MW] for 1 second to program. • 3 beeps sound and the VFO mode is automatically selected. • T he memory channel number advances to the next scan edge channel, 1b, 2b or 3b, when continuing to push [MW] after programming. b T o program a frequency for the other scan edge channels, repeat steps z to v. 31 [i.e.]: Programming 145.300 MHz into scan edge 1A. Push [V/MHz]. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Rotate [DIAL] to set the frequency. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Push [S.MW]. MUTE NAR MID LOW LOCK SET ANM MONI DUP LOW DIGITAL PRIO AO BUSY T-SCAN TONE PRIO M/CALL SCAN V/ MHz Rotate [DIAL] to select the scan edge channel. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Hold down [MW] (S.MW) for 1 second. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Beep Beep Beep MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz [i.e.]: Programming 145.800 MHz into scan edge 1b. Push . MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Push . MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Push then . MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Push MUTE NAR MID LOW LOCK SET ANM MONI / DUP LOW . DIGITAL PRIO AO BUSY T-SCAN TONE PRIO M/CALL SCAN V/ MHz Push then hold down for 1 second. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Beep Beep Beep MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

31
7
SCAN OPERATION
Scan edges programming
Scan edges can be programmed in the same manner
as memory channels. Scan edges are programmed
into scan edges, 1A/1b to 3A/3b, in memory channel
sheet.
q
Set the desired edge frequency in the VFO mode:
w
Push
[MW]
(S.MW).
• The “
” icon and channel number blink.
e
Rotate
[DIAL]
to select one of scan edge channels,
1A, 2A or 3A.
r
Hold down
[MW]
(S.MW) for 1 second to store it.
• 3 beeps sound and the transceiver automatically
returns to the VFO mode.
• Scan edge 1b, 2b or 3b is automatically selected
when continuing to hold down
[MW]
(S.MW) after
programming.
t
To program a frequency for the other pair of scan
edges, the 1b, 2b or 3b, repeat steps
q
through
r
.
• If the same frequency is programmed into a pair of
scan edges, the programmed scan cannot start.
Using the HM-133V
z
Set the desired frequency in the VFO mode.
x
Push
[FUNC]
, and then
[MW]
.
c
Push
[
Y
]
or
[
Z
]
to select the scan edge channels,
1A, 2A or 3A.
v
Push
[FUNC]
, and then hold down
[MW]
for
1 second to program.
• 3 beeps sound and the VFO mode is automatically
selected.
• The memory channel number advances to the next
scan edge channel, 1b, 2b or 3b, when continuing
to push
[MW]
after programming.
b
To program a frequency for the other scan edge
channels, repeat steps
z
to
v
.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Push
[V/MHz]
.
Rotate
[DIAL]
to set the frequency.
Push
[S.MW]
.
Rotate
[DIAL]
to select the scan edge channel.
Hold down
[MW]
(S.MW) for 1 second.
Beep
Beep
Beep
[i.e.]:
Programming 145.300 MHz into scan edge 1A.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Beep
Beep
Beep
Push
.
Push
then
.
Push
/
.
Push
then hold down
for 1 second.
Push
.
[i.e.]:
Programming 145.800 MHz into scan edge 1b.