Icom IC-2300H Instruction Manual - Page 56

Time-out timer, Auto power OFF, Repeater lockout, Key-touch beep, Squelch delay, Squelch type - reset

Page 56 highlights

11 OTHER FUNCTIONS DDKey-touch beep Turn the confirmation beeps ON (default) or OFF. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz DDTime-out timer To prevent accidental prolonged transmission, the transceiver has a time-out timer. The function inhibits continuous transmissions longer than the set time pe- riod (1-30 minutes). • TOT-OF : Turns OFF the function. (default) • TOT-1-30 : T he transmission is cut OFF after the set time period ends. MUTE NAR MID LOW LOCK SET ANM MONI DUP LOW DIGITAL PRIO AO BUSY T-SCAN TONE PRIO M/CALL SCAN V/ MHz MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz DDAuto repeater U.S.A. version only The Auto Repeater function automatically turns the duplex setting and tone encoder ON or OFF when the operating frequency falls within or outside of the general repeater output frequency range (145.200- 145.495 MHz, 146.610-146.995 MHz and 147.000- 147.395 MHz). The offset and repeater tone frequencies are not changed by the Auto Repeater function; reset these frequencies, if necessary. • OF : The Auto Repeater function is OFF. • R1 : Activates for duplex only. (default) • R2 : Activates for duplex and tone. MUTE NAR MID LOW LOCK SET ANM MONI DUP LOW DIGITAL PRIO AO BUSY T-SCAN TONE PRIO M/CALL SCAN V/ MHz MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz DDAuto power OFF The transceiver can be automatically turned OFF, when no key operation is performed for the specified time period. 30 min., 1 hour, 2 hours and OFF (default) are selectable. The time period is retained, even if the transceiver is turned OFF by the auto power OFF function. To cancel the function, select "OF" (OFF). MUTE NAR MID LOW LOCK SET ANM MONI DUP LOW DIGITAL PRIO AO BUSY T-SCAN TONE PRIO M/CALL SCAN V/ MHz MUTE NAR MID LOW LOCK SET ANM MONI AO DIGITAL PRIO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz DDRepeater lockout Set the transmission lockout (temporary transmission inhibit) capability. • OF : No lockout is activated. (default) • RP : The repeater lockout is turned ON. • BU : The busy lockout is turned ON. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Busy lock-out setting MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Repeater lock-out setting DDSquelch delay Set the squelch delay to short or long. The delay prevents the squelch from repeatedly opening and closing, while receiving the same signal. • S : Short squelch delay. (default) • L : Long squelch delay. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Short squelch delay setting MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Long squelch delay setting DDSquelch type Set the squelch type to OFF (Noise squelch), S-meter Squelch or Squelch Attenuator. • OF : Noise squelch (default) • SS : S-meter squelch The S-meter squelch allows you to set a mini- mum signal level needed to open the squelch. Rotate [SQL] to adjust the S-meter squelch lev- el. The S-meter is automatically activated when [SQL] is rotated further than the 12 o'clock position. • AT : Squelch Attenuator The attenuator is automatically activated when [SQL] is rotated further than the 12 o'clock position. Approximately 20 dB of attenuation is obtained at the maximum setting. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz Noise squelch (default) MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz S-meter squelch MUTE NAR MID LOW LOCK SET ANM MONI Squelch atte NAR MID LOW LOCK SET ANM MONI DUP LOW ATT AO T-SCAN TONE PRIO M/CALL SCAN V/ MHz Appears While the squelch attenuator is turned ON. ([DIAL] is set between the 12 o'clock and fully clockwise positions.) NAR MID LOW LOCK SET ANM MONI DUP LOW S SQL Appears T-SCAN TONE PRIO M/CALL SCAN V/ MHz While the S-meter squelch is turned ON. 48 ([DIAL] is set between the 12 o'clock and fully clockwise positions.)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

48
11
OTHER FUNCTIONS
Key-touch beep
D
Turn the confirmation beeps ON (default) or OFF.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Time-out timer
D
To prevent accidental prolonged transmission, the
transceiver has a time-out timer. The function inhibits
continuous transmissions longer than the set time pe-
riod (1–30 minutes).
• TOT-OF
: Turns OFF the function. (default)
• TOT-1–30
: The transmission is cut OFF after the
set time period ends.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Auto repeater
D
U.S.A. version only
The Auto Repeater function automatically turns the
duplex setting and tone encoder ON or OFF when
the operating frequency falls within or outside of the
general repeater output frequency range (145.200–
145.495 MHz, 146.610–146.995 MHz and 147.000–
147.395 MHz).
The offset and repeater tone frequencies are not
changed by the Auto Repeater function; reset these
frequencies, if necessary.
• OF :The Auto Repeater function is OFF.
• R1 : Activates for duplex only. (default)
• R2 : Activates for duplex and tone.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Auto power OFF
D
The transceiver can be automatically turned OFF, when
no key operation is performed for the specified time pe-
riod. 30 min., 1 hour, 2 hours and OFF (default) are se-
lectable.
The time period is retained, even if the transceiver is
turned OFF by the auto power OFF function. To cancel
the function, select “OF” (OFF).
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO
AO
BUSY
MUTE
NAR
MID
LOW
Repeater lockout
D
Set the transmission lockout (temporary transmission
inhibit) capability.
• OF : No lockout is activated. (default)
• RP : The repeater lockout is turned ON.
• BU : The busy lockout is turned ON.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Busy lock-out setting
Repeater lock-out setting
Squelch delay
D
Set the squelch delay to short or long. The delay pre-
vents the squelch from repeatedly opening and closing,
while receiving the same signal.
•S
: Short squelch delay. (default)
•L
: Long squelch delay.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
Short squelch delay setting
Long squelch delay setting
Squelch type
D
Set the squelch type to OFF (Noise squelch), S-meter
Squelch or Squelch Attenuator.
• OF : Noise squelch (default)
• SS : S-meter squelch
The S-meter squelch allows you to set a mini-
mum signal level needed to open the squelch.
Rotate
[SQL]
to adjust the S-meter squelch lev-
el. The S-meter is automatically activated when
[SQL]
is rotated further than the 12 o'clock posi
-
tion.
• AT
: Squelch Attenuator
The attenuator is automatically activated when
[SQL]
is rotated further than the 12 o'clock posi
-
tion. Approximately 20 dB of attenuation is ob-
tained at the maximum setting.
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO
MUTE
NAR
MID
LOW
S-meter squelch
Noise squelch (default)