Intel SR1630HGP Service Guide - Page 48
Normal Integrated BMC functionality is disabled with the Force Integrated BMC Update
![]() |
UPC - 735858211901
View all Intel SR1630HGP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
board provides an Integrated BMC Force Update jumper, which forces the Integrated BMC into the proper update state. You should complete the following procedure in the event the standard Integrated BMC firmware update process fails. Note: Normal Integrated BMC functionality is disabled with the Force Integrated BMC Update jumper set to the enabled position. The server should never be run with the Integrated BMC Force Update jumper set in this position. This jumper setting should only be used when the standard firmware update process fails. This jumper should remain in the default / disabled position when the server is running normally. 1. Power down and remove the AC power cord. 2. Open the server chassis. For instructions, refer to your server chassis documentation. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the enabled position (covering pins 2 and 3). 4. Close the server chassis. 5. Reconnect the AC cord and power up the server. 6. Perform the Integrated BMC firmware update procedure as documented in the README.TXT file included in the given Integrated BMC firmware update package. After successful completion of the firmware update process, the firmware update utility may generate an error stating the Integrated BMC is still in update mode. 7. Power down and remove the AC power cord. 8. Open the server chassis. 9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC cord and power up the server. 26 Intel® Server System SR1630GP / SR1630HGP Service Guide
![](/manual_guide/products/intel-sr1630gp-service-guide-75d595d/48.png)