Printer Tests, 4.3.8 Printer Test List and Test Description, TEST NAME, TEST DESCRIPTION
View all Konica Minolta EFI Pro 16h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
4.3.7 Printer Tests To run printer tests, open the EFI Pro 16hControl window and select a test print from the menu and choose the Print icon to conduct that test print. 1 2 Figure 4-19: : Print Icon 1 Select test in list 2 Choose Print icon to print selected test 4.3.8 Printer Test List and Test Description A list of tests and the related description of each test is provided below. Operators only use the Nozzle Check test. Other Print Tests are used by Field Service Engineers. TEST NAME Nozzle Check Head Rotation Align Nozzle to Nozzle Align Internal Right Align Internal BiDi align TEST DESCRIPTION The Nozzle Check test provides a test print that shows whether all print heads are working properly Head Rotation Alignment checks if print heads are perpendicular with the X-Axis Nozzle to Nozzle Alignment checks if print heads are aligned with each other Internal Right Align checks whether printed lines intersect at the zero position Internal BIDI Alignment (BIDI = Bi-Directional) checks whether printed lines intersect at the zero position Document ID: OMM-00135 Revision A 59