Lantronix XPress-DR XPress-DR / XPress-DR-IAP - User Guide - Page 104

Channel Parameters, Table 26 - Channel Parameters

Page 104 highlights

UDP 8.3.1 Channel Parameters Use the following table to select setup record parameters for Channels 1: Table 26 - Channel Parameters Byte(s) (Channel 1) 16 17 18 19 20-21 22-23 24-27 28 29 30 31 32-33 34 35 36-47 48-63 Function Interface Mode (see Table 27 - Interface Mode Options) Line Speed Bits 7-5: Reserved Bits 4-0: Baud Rate (see Table 29 - Baud Rate Settings) Flow Control (see Table 30 - Flow Control Options) Reserved Own TCP port low-byte, high-byte (Intel) Remote TCP port low byte, high-byte (Intel) Remote IP address (low/high low/high) Connect Mode (see Table 31 - Connect Mode Options) Disconnect Mode (see Table 32 - Disconnect Mode Options) Disconnect w/ inactivity time-out, minutes (00 if unused) Disconnect w/ inactivity time-out, seconds (00 if unused) Characters to trigger send immediately (sendchar) Flush mode (see Table 33 - Flush Mode Options) Pack Control (see Table 34 - Pack Control Options) Reserved (0) a) Terminal name for Telnet terminal type option (15 characters max), 0-terminated. If set and Bit 6 in Disconnect Mode is set, Telnet connection will be assumed. b) Password for Passworded Socket Connection (Bit 4 in Disconnect Mode Set). 8-8 DSTni-XPress DR User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

UDP
8.3.1 Channel Parameters
Use the following table to select setup record parameters for Channels 1:
Table 26 - Channel Parameters
Byte(s)
(Channel 1)
Function
16
Interface Mode (see
Table 27 - Interface Mode Options
)
17
Line Speed
Bits 7-5: Reserved
Bits 4-0: Baud Rate (see
Table 29 - Baud Rate Settings
)
18
Flow Control (see
Table 30 - Flow Control Options
)
19
Reserved
20-21
Own TCP port low-byte, high-byte (Intel)
22-23
Remote TCP port low byte, high-byte (Intel)
24-27
Remote IP address (low/high low/high)
28
Connect Mode (see
Table 31 - Connect Mode Options
)
29
Disconnect Mode (see
Table 32 - Disconnect Mode Options
)
30
Disconnect w/ inactivity time-out, minutes (00 if unused)
31
Disconnect w/ inactivity time-out, seconds (00 if unused)
32-33
Characters to trigger send immediately (sendchar)
34
Flush mode (see
Table 33 - Flush Mode Options
)
35
Pack Control (see
Table 34 - Pack Control Options
)
36-47
Reserved (0)
48-63
a) Terminal name for Telnet terminal type option (15 characters max),
0-terminated. If set and Bit 6 in Disconnect Mode is set, Telnet
connection will be assumed.
b) Password for Passworded Socket Connection (Bit 4 in Disconnect
Mode Set).
8-8
DSTni-XPress DR User Guide