Panasonic KX-MB2061 Operating Instructions - Page 40
Scanning from a computer, Pull Scan
View all Panasonic KX-MB2061 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
4. Scanner 4.1.7 Scan to SMB folder (LAN connection only) You can send the scanned image to a folder on the network. Important: R Program the SMB folder settings beforehand (page 93). 1 Set the original (page 25). 2 MScanN 3 Press MCN or MDN repeatedly to select "SMB FOLDER". A MSetN 4 Press MCN or MDN repeatedly to select the folder to which you want to send the scanned image. A MSetN 5 If necessary, change the scanning settings. Press MEN, press MCN or MDN repeatedly to select the desired setting. A MSetN R If you want to scan several pages and save as a single file, select PDF as the file format. 6 When using the scanner glass: MStartN A The unit will scan 1 page. Place the next document on the scanner glass and press MSetN. Repeat this until all the documents are scanned, then press MStartN. When using the automatic document feeder: MStartN R The scanned image will be automatically saved in the selected folder on the network. 7 After you finish scanning, press MStopN to reset the settings you set in step 5. Note: R To stop scanning, see page 108. R You can save the images in TIFF, JPEG or PDF formats. R If this function does not perform properly, consult your network administrator. This unit's SMB function does not support NTMLv2 and SMB signatures. 4.2 Scanning from a computer (Pull Scan) Note: R When scanning a document, we recommend using the scanner glass rather than the automatic document feeder for better results. R Do not open the document cover when scanning a document with the automatic document feeder. 4.2.1 Using Multi-Function scan application By clicking an application icon, the selected application starts automatically after scanning. 1 Set the original (page 25). 2 Start Multi-Function Station. A [Scan] 3 Click the desired application icon. R When you click [Custom], the pre-programmed application starts. R To cancel scanning while the documents are being scanned, click [Cancel]. Note: R You can change the scanning settings beforehand for each application (page 34). R When you point to an application icon, the scanning settings for that application are displayed as a tooltip. R The scanned image will be automatically saved in the folder selected in the [Settings] window (page 34). 4.2.2 Using Multi-Function Viewer 1 Set the original (page 25). 2 Start Multi-Function Station. 3 [Utilities] A [Viewer] R [Multi-Function Viewer] will appear. 4 Click the [Scan] icon in the [Multi-Function Viewer] window. R The unit's name dialog box will appear. 5 If necessary, change the scanning settings on your computer. R To preview the scanned image, click [Preview]. You can drag the frame to specify the scanning area. If you change the scan settings, click [Preview] to refresh the scanned image. If you use the automatic document feeder, only the first page will be previewed. When you need to refresh the scanned image, set the document to preview again. 6 [Scan] R If you preview the scanned image using the automatic document feeder in step 5, set the document again and click [Scan]. R The scanned image will be displayed in the [Multi-Function Viewer] window after scanning. 40