Digital Interface Modes (Function 35), Printing the DI Parameter List
View all Ricoh SFX2000M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
ADDITIONAL PROCEDURES Digital Interface Modes (Function 35) The SFX2000M recognizes four types of protocols for communication through the digital interface, (1) MIL-STD-188-161D, (2) Ricoh MG3, (3) Compatible, and (4) Asynchronous. Each type is defined further by parameters that can be selected during programming. (The available selections are shown preceding the programming directions of each protocol.) The SFX2000M arrives from the factory with 13 pre-programmed Digital Interface protocol modes numbered 00 to 12. With Function 35, you can add up to 87 new protocols. To facilitate service and technical assistance we advise that you create new protocol modes instead of revising the pre- programmed ones. A list of programmed protocols, titled the DI Parameter List, can be printed with either Function 35 or Function 47 (page 73). Printing the DI Parameter List Ready READY COMPATIBLE 10:00AM MODE06 Press Function 3 5 Yes MODE NO. KPAD/e PRINT LISTe/SEARCHf Press Y Start When finished the PRINT LIST display will return. Programming and Editing DI Protocol Modes MIL-STD Protocol Press No to display the next choice. Press Yes to make a selection. Parameter First Choice Next Choice Next Next Protocol Asynchronous MIL-STD Ricoh MG3 Compatible Parameter First Choice Next Choice Handshake No (Broadcast) Yes Line (Telephone) Leased (Point to Point) Dial up (Switched) Compression Yes (MH) No (Uncompressed) Duplex Modem Full Half FEC (Forward Error Correction) No (Off) Yes (On) 40 SFX2000M User Guide