Sony DVWM2000 Product Manual (dvwm2000 installation manual) - Page 23
Monitor output level switching fixed or variable
View all Sony DVWM2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
1-10. Switch Settings on Circuit Boards Audio output level settings Channel CH1 CH2 CH3 CH4 Ref. No. S501 S601 S701 S801 Switches state (\ : Knob position) N O N O 4 3 2 1 4 3 2 1 +4 dBm/600 Z (Factory setting) 0 dBm/600 Z Audio output headroom settings Channel CH1 CH2 CH3 CH4 Ref. No. S500 S600 S700 S800 Switches state (\ : Knob position) N O N O 4 3 2 1 4 3 2 1 20 dB (Factory setting) 18 dB Monitor output level settings Channel L Ref. No. S902 Switches state (\ : Knob position) 1 O 2 N 3 4 _3 dBm/600 Z _20 dBm/600 Z N O N O 4 3 2 1 4 3 2 1 16 dB 12 dB 1 O 2 N 3 4 N O N O N O N O 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 R S1002 +4 dBm/600 Z 0 dBm/600 Z (Factory setting) Monitor output headroom settings Channel L Ref. No. S900 Switches state (\ : Knob position) _3 dBm/600 Z _20 dBm/600 Z N O N O N O N O 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 R S1000 20 dB 18 dB (Factory setting) 16 dB 12 dB Monitor output level switching (fixed or variable) When the variable level is selected, the level is adjusted with the PHONE level control knob. Channel L Ref. No. S901 R S1001 Switch state (\ : Knob position) Fixed 1 O 2 N (Factory setting) Variable 1 O 2 N HDW-2000/M2000/M2000P/S2000/S2000P/M2100/M2100P, DVW-2000/2000P/M2000/M2000P MSW-2000/A2000/A2000P/M2000/M2000P/M2000E/M2000EP/M2100/M2100P/M2100E/M2100EP 1-17