Sony DVWM2000 Product Manual (dvwm2000 installation manual) - Page 33

-2., VTR Constant Values Settings of Editor - dvw m2000p

Page 33 highlights

1-15. Settings and Adjustment when External Equipment is Connected 1-15-2. VTR Constant Values Settings of Editor Set the VTR constant values according to the table 1-15-2 below when the editor which needs the setting of VTR constant values is connected. Moreover, the change of VTR constant values are required when the operation mode (HDW series : 50/59.94 Hz mode, DVW/MSW series : 525/625 mode) is switched by setup menu of this unit. n When remote-controlling this unit by the editor, set the setup menu ITEM-401: FUNCTION MODE AFTER CUE-UP to "STOP". Table 1-15-2. VTR Constant Values Settings of Editor Model Operation VTR CONSTANT 1 VTR CONSTANT 2 Mode Data No. Data No. 123456 78123456 78 HDW-2000, HDW-M2000, 59.94, 29.97P 20 E2 00 96 07 07 03 8A* 0D 08 00 00 81 3D FF 5A HDW-M2000P, 50, 25P 21 E2 00 7D 07 07 03 8A* 0D 07 00 00 83 3B FF 4B HDW-S2000, HDW-S2000P 24P, 23.98P 22 E3 00 78 07 07 03 8A* 0D 07 00 00 83 3B FF 4B HDW-M2100, 59.94, 29.97P 20 E3 00 96 07 07 03 8A* 0D 08 00 00 81 3D FF 5A HDW-M2100P 50, 25P 21 E3 00 7D 07 07 03 8A* 0D 07 00 00 83 3B FF 4B 24P, 23.98P 22 E3 00 78 07 07 03 8A* 0D 07 00 00 83 3B FF 4B DVW-2000, DVW-2000P 525/60 625/50 B0 14 00 96 07 07 05 8A* 0A 07 FB 00 81 4B FF 5A B1 14 00 7D 07 07 05 8A* 0A 07 FB 00 83 3B FF 4B DVW-M2000, DVW-M2000P 525/60 625/50 B0 04 00 96 07 07 05 8A* 0A 07 FB 00 81 4B FF 5A B1 04 00 7D 07 07 05 8A* 0A 07 FB 00 83 3B FF 4B MSW-2000 525/60 625/50 B0 62 00 96 07 07 05 8A* 0A 07 FB 00 81 4B FF 5A B1 62 00 7D 07 07 05 8A* 0A 07 FB 00 83 3B FF 4B MSW-A2000, MSW-A2000P 525/60 625/50 B0 61 00 96 07 07 05 8A* 0A 07 FB 00 81 4B FF 5A B1 61 00 7D 07 07 05 8A* 0A 07 FB 00 83 3B FF 4B MSW-M2000, MSW-M2000P, MSW-M2000E, MSW-M2000EP 525/60 625/50 B0 60 00 96 07 07 B1 60 00 7D 07 07 05 8A* 0A 07 FB 00 05 8A* 0A 07 FB 00 81 4B 83 3B FF 5A FF 4B MSW-M2100, MSW-M2100P, MSW-M2100E, MSW-M2100EP 525/60 625/50 B0 63 00 96 07 07 B1 63 00 7D 07 07 05 8A* 0A 07 FB 00 05 8A* 0A 07 FB 00 81 4B 83 3B FF 5A FF 4B (Standard value is expressed in hexadecimal.) *: Set the data of No.8 of the VTR CONSTANT 1 to "0A" for the following editors. . BVE-900 ROM versions earlier than 1.08 . BVE-600 ROM versions earlier than 1.01 HDW-2000/M2000/M2000P/S2000/S2000P/M2100/M2100P, DVW-2000/2000P/M2000/M2000P MSW-2000/A2000/A2000P/M2000/M2000P/M2000E/M2000EP/M2100/M2100P/M2100E/M2100EP 1-27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

1-27
HDW-2000/M2000/M2000P/S2000/S2000P/M2100/M2100P, DVW-2000/2000P/M2000/M2000P
MSW-2000/A2000/A2000P/M2000/M2000P/M2000E/M2000EP/M2100/M2100P/M2100E/M2100EP
1-15-2.
VTR Constant Values Settings of Editor
Set the VTR constant values according to the table 1-15-2 below when the editor which needs the setting
of VTR constant values is connected. Moreover, the change of VTR constant values are required when
the operation mode (HDW series : 50/59.94 Hz mode, DVW/MSW series : 525/625 mode) is switched by
setup menu of this unit.
n
When remote-controlling this unit by the editor, set the setup menu ITEM-401: FUNCTION MODE
AFTER CUE-UP to
STOP
.
Table 1-15-2. VTR Constant Values Settings of Editor
(Standard value is expressed in hexadecimal.)
*
:
Set the data of No.8 of the VTR CONSTANT 1 to
0A
for the following editors.
.
BVE-900 ROM versions earlier than 1.08
.
BVE-600 ROM versions earlier than 1.01
1-15. Settings and Adjustment when External Equipment is Connected
Model
Operation
Mode
MSW-A2000,
MSW-A2000P
525/60
VTR CONSTANT 1
1
2
3
4
5
6
7
8
B0
61
00
96
07
07
05
8A
Data No.
*
VTR CONSTANT 2
1
2
3
4
5
6
7
8
0A
07
FB
00
81
4B
FF
5A
625/50
B1
61
00
7D
07
07
05
8A
*
0A
07
FB
00
83
3B
FF
4B
MSW-2000
525/60
B0
62
00
96
07
07
05
8A
*
0A
07
FB
00
81
4B
FF
5A
625/50
B1
62
00
7D
07
07
05
8A
*
0A
07
FB
00
83
3B
FF
4B
HDW-2000,
HDW-M2000,
HDW-M2000P,
HDW-S2000,
HDW-S2000P
59.94, 29.97P
20
E2
00
96
07
07
03
8A
*
0D
08
00
00
81
3D
FF
5A
50, 25P
21
E2
00
7D
07
07
03
8A
*
*
0D
07
00
00
83
3B
FF
4B
24P, 23.98P
22
E3
00
78
07
07
03
8A
0D
07
00
00
83
3B
FF
4B
*
24P, 23.98P
22
E3
00
78
07
07
03
8A
0D
07
00
00
83
3B
FF
4B
HDW-M2100,
HDW-M2100P
59.94, 29.97P
20
E3
00
96
07
07
03
8A
*
0D
08
00
00
81
3D
FF
5A
50, 25P
21
E3
00
7D
07
07
03
8A
*
0D
07
00
00
83
3B
FF
4B
MSW-M2000,
MSW-M2000P,
MSW-M2000E,
MSW-M2000EP
525/60
B0
60
00
96
07
07
05
8A
*
0A
07
FB
00
81
4B
FF
5A
625/50
B1
60
00
7D
07
07
05
8A
*
0A
07
FB
00
83
3B
FF
4B
MSW-M2100,
MSW-M2100P,
MSW-M2100E,
MSW-M2100EP
525/60
B0
63
00
96
07
07
05
8A
*
0A
07
FB
00
81
4B
FF
5A
625/50
B1
63
00
7D
07
07
05
8A
*
0A
07
FB
00
83
3B
FF
4B
DVW-2000,
DVW-2000P
525/60
B0
14
00
96
07
07
05
8A
*
0A
07
FB
00
81
4B
FF
5A
625/50
B1
14
00
7D
07
07
05
8A
*
0A
07
FB
00
83
3B
FF
4B
DVW-M2000,
DVW-M2000P
525/60
B0
04
00
96
07
07
05
8A
*
0A
07
FB
00
81
4B
FF
5A
625/50
B1
04
00
7D
07
07
05
8A
*
0A
07
FB
00
83
3B
FF
4B
Data No.