Xerox 2135N Quick Reference Guide - Page 87
Consumable count initialization
UPC - 042215474689
View all Xerox 2135N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
Consumable count initialization This test menu item allows you to initialize the print engine's consumable counts and registration set points. 1. Enter the diagnosis mode by pressing and holding the Menu (1) and Enter (4) keys as you turn on the printer. 2. Press the Menu (1, 5) keys to scroll through the list of test until NV-RAM INITIAL appears on the upper display. 3. Press the Item (2, 6) keys to select Table 1. The table indicates which NVRAM items will be initialized. Refer to the table printed below. 4. Press and hold Value (3) for 10 seconds to initialize the items of the selected table. The front panel display NV-RAM INITIAL blinks eight times. 5. Press Enter (4) to exit the test mode. Table 1: Initialization items - consumables Initialization Item Drum Counter Black Yellow Magenta Cyan Belt Unit Counter Fuser Unit Counter Toner Counter Black Yellow Magenta Cyan Detail Initializes the drum counter's count after the replacement of a drum. Initializes the print count after the replacement of a transfer belt unit. Initializes the fuser's print count after the replacement of a fuser unit. Initializes the toner use count after a toner cartridge is replaced 74 Phaser 2135 Color Printer