Xerox Z750/N Troubleshooting Guide - Page 98
Cleaning the sensor, Cleaning other rollers, Advanced Features and Troubleshooting Manual
![]() |
UPC - 042215455084
View all Xerox Z750/N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Cleaning Phaser 750 Printers Cleaning the sensor If your printer's front panel displays Error 30, clean the sensor inside the printer. 1. Turn the printer off and open the printer's front door. 2. Remove the Imaging Unit: a. Loosen the two thumbscrews by turning them counterclockwise. b. Turn the lower lever 180 degrees counterclockwise. c. Slide the Imaging Unit out of the printer and cover it to protect it from light exposure. a b 0236-39 3. Use a dry, lint-free cloth to wipe the sensor (inside the slot). 9698-64 4. Re-insert the Imaging Unit. 5. Close the printer's front door and turn on the printer. Cleaning other rollers When you clean any of the other rollers in the printer, always use a lint-free cloth. Caution Do not clean the transfer roller; alcohol and pressing on the roller can damage the roller and cause print-quality problems. Advanced Features and Troubleshooting Manual 89