ground leaf spring., The eject sensor actuator may also be removed when removing the fixing unit.
UPC - 012502525394
View all Brother International MFC-P2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Note: When reassembling the MP rear sheet feeder, remove the old grease and apply a suitable amount of grease (2 rice-grain size) between the heat sink of the motor and the ground leaf spring. (Refer to the figure below.) Ground leaf spring Grease: FLOIL GE-676 (or FLOIL GE-334C) Motor heat sink 6.2 mm Fig. 3-19 3.8 Fixing Unit (1) Remove the two M4x16 tapping screws. (2) Lifting the fixing unit, disconnect the thermistor connector on the EL PCB first, then the two heater harness connectors. Taptite, cup M4x16 Fixing Unit Taptite, cup M4x16 EL PCB Thermistor harness Thermistor connector Heater harness (Brown) Heater harness (Blue) Fig. 3-20 Note: The eject sensor actuator may also be removed when removing the fixing unit. In this case be sure to re-assemble the eject sensor actuator when re-assembling the fixing unit. III-14