Brother International MFC-P2000 Service Manual - Page 76

Is the problem solved when the, drum unit is replaced?

Page 76 highlights

I-2 Dark Possible cause Main PCB failure Laser unit failure Step 1 2 Check Is the problem solved after the main PCB is replaced? Is the problem solved after the laser unit is replaced? Result Remedy Yes Replace the main PCB. Yes Replace the laser unit. Possible cause Corona failure (soiled wire) Corona failure (contact failure) Drum unit failure High-voltage power supply PCB Main PCB Panel sensor PCB Step 1 2 3 4 5 6 Check Is the corona wire dirty? Are the corona electrodes between the printer body and drum unit dirty? Is the problem solved when the drum unit is replaced? Are there any disconnected connectors? Are there any disconnected connectors? Are there any disconnected connectors? Result Yes No Yes No No No Remedy Clean the corona wire by using the wire cleaner. Clean both electrodes. Replace the drum unit with a new one. Replace the highvoltage power supply PCB. Replace the main PCB. Replace the panel sensor PCB. GND contacts (Fig.4-5) ➇ ➅ IV-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294

IV-7
I-2
Dark
<Scanning>
Possible cause
Step
Check
Result
Remedy
Main PCB
failure
1
Is the problem solved after the
main PCB is replaced?
Yes
Replace the main PCB.
Laser unit failure
2
Is the problem solved after the
laser unit is replaced?
Yes
Replace the laser unit.
<Printing>
Possible cause
Step
Check
Result
Remedy
GND
contacts
(Fig.4-5)
Corona failure
(soiled wire)
1
Is the corona wire dirty?
Yes
Clean the corona wire
by using the wire
cleaner.
Corona failure
(contact failure)
2
Are the corona electrodes
between the printer body and
drum unit dirty?
No
Clean both electrodes.
Drum unit failure
3
Is the problem solved when the
drum unit is replaced?
Yes
Replace the drum
unit with a new one.
High-voltage
power supply
PCB
4
Are there any disconnected
connectors?
No
Replace the high-
voltage power supply
PCB.
Main PCB
5
Are there any disconnected
connectors?
No
Replace the main
PCB.
Panel sensor
PCB
6
Are there any disconnected
connectors?
No
Replace the panel
sensor PCB.