Brother International MFC-P2000 Service Manual - Page 78

All black, the panel sensor PCB

Page 78 highlights

I-4 All black Possible cause CIS harness connection CIS unit failure Sensor harness connection Main PCB failure Step Check 1 Is the CIS harness connected securely? 2 Is the problem solved after the CIS unit is replaced? 3 Is the sensor harness connected between the main PCB and the scanner sensor PCB securely? 4 Is the problem solved after the main PCB is replaced? Result Remedy No Reconnect the CIS harness. Yes Replace the CIS unit. No Reconnect the sensor harness. Yes Replace the main PCB. Possible cause Corona failure Harness connection High-voltage power supply PCB Ditto Main PCB Panel sensor PCB Step 1 2 3 4 5 6 7 Check Is the corona wire of the drum unit broken? Are the electric terminal springs in the printer body and the electrode on the bottom face of the drum unit dirty? Is the laser unit connected with the panel sensor PCB correctly? Is the problem solved after high-voltage power supply PCB replaced? Perform the same check as in step 3. Is the problem solved after main PCB is replaced? Is the problem solved after the panel sensor PCB is replaced? Result Yes Yes No Yes Yes Yes Yes Remedy Replace the drum unit. Clean the terminals in the printer and on the drum. Check the harness connection between the laser unit and the panel sensor PCB. Replace the highvoltage power supply PCB. Replace the panel sensor PCB. Replace the main PCB. Replace the panel sensor PCB. GND contacts (Fig.4-5) ➅ IV-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294

IV-9
I-4
All black
<Scanning>
Possible cause
Step
Check
Result
Remedy
CIS harness
connection
1
Is the CIS harness connected
securely?
No
Reconnect the CIS harness.
CIS unit failure
2
Is the problem solved after the
CIS unit is replaced?
Yes
Replace the CIS unit.
Sensor harness
connection
3
Is the sensor harness
connected between the main
PCB and the scanner sensor
PCB securely?
No
Reconnect the sensor harness.
Main PCB
failure
4
Is the problem solved after the
main PCB is replaced?
Yes
Replace the main PCB.
<Printing>
Possible cause
Step
Check
Result
Remedy
GND
contacts
(Fig.4-5)
Corona failure
1
Is the corona wire of the drum
unit broken?
Yes
Replace the drum
unit.
2
Are the electric terminal
springs in the printer body and
the electrode on the bottom
face of the drum unit dirty?
Yes
Clean the terminals
in the printer and on
the drum.
Harness
connection
3
Is the laser unit connected with
the panel sensor PCB
correctly?
No
Check the harness
connection between
the laser unit and the
panel sensor PCB.
High-voltage
power supply
PCB
4
Is the problem solved after
high-voltage power supply
PCB replaced?
Yes
Replace the high-
voltage power supply
PCB.
Ditto
5
Perform the same check as in
step 3.
Yes
Replace the panel
sensor PCB.
Main PCB
6
Is the problem solved after
main PCB is replaced?
Yes
Replace the main
PCB.
Panel sensor
PCB
7
Is the problem solved after the
panel sensor PCB is replaced?
Yes
Replace the panel
sensor PCB.