(3) Remove the one M4x12 screw to remove the inlet holder. Then, remove the AC inlet and the PCB. Note: When re-assembling the inlet holder and AC inlet, be sure to insert part A of the holder into the hole of the ferrite core. Inlet Holder Main Cover A AC Inlet Ferrite core Fig. 3-35 3.14 High-voltage Power Supply PCB ASSY (1) Remove the one M4x12 screw securing the high-voltage power supply PCB ASSY. (2) Remove the film covering the PCB. (2) Disconnect the HV flat cable from the PCB. Taptite, bind M4x12 High-voltage Power Supply PCB ASSY Insulation Sheet HV flat cable Fig. 3-36 III-22 Main Cover
III-22
(3)
Remove the one M4x12 screw to remove the inlet holder.
Then, remove the
AC
inlet
and the PCB.
Note:
When re-assembling the inlet holder and AC inlet, be sure to insert part
A
of the holder
into the hole of the ferrite core.
Fig. 3-35
3.14
High-voltage Power Supply PCB ASSY
(1)
Remove the one M4x12 screw securing the
high-voltage power supply PCB
ASSY.
(2)
Remove the film covering the PCB.
(2)
Disconnect the HV flat cable from the PCB.
Fig. 3-36
Taptite, bind
M4x12
Main Cover
HV flat cable
High-voltage Power
Supply PCB ASSY
Inlet Holder
AC Inlet
Main Cover
Insulation Sheet
Ferrite core
A