Canon BJC 6000 Service Manual - Page 40
Interface Specifications, AUTO FEED XT - computer cable
View all Canon BJC 6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Part 2: Product Specifications 2.3 Interface Specifications 1) Interface type IEEE1284-compatible parallel interface 2) Data transfer method 8-bit parallel (supporting nibble/ECP mode) 3) Signal level Low level: +0.0 to +0.8 V High level: +2.4 to +5.0 V 4) I/O Each signal pulled up with +5 V. 5) Interface cable Type: Shielded twisted-pair cable Wire size: AWG 28 or larger Length: 2.0 m max. 6) Interface connectors Printer connector: Amphenol 57-40360 or equivalent Cable connector: Amphenol 57-30360 or equivalent 7) I/O signals and pin assignment Compatible mode No. Signal I/O No. Signal 1 STROBE IN 19 STROBE-RET*1 2 DATA1 IN 20 DATA1-RET 3 DATA2 IN 21 DATA2-RET 4 DATA3 IN 22 DATA3-RET 5 DATA4 IN 23 DATA4-RET 6 DATA5 IN 24 DATA5-RET 7 DATA6 IN 25 DATA6-RET 8 DATA7 IN 26 DATA7-RET 9 DATA8 IN 27 DATA8-RET 10 ACKNLG OUT 28 ACKNLG-RET 11 BUSY OUT 29 BUSY-RET 12 P.E. OUT 30 P.E.-RET 13 SELECT OUT 31 INIT 14 AUTO FEED XT*4 IN 32 ERROR 15 N.C*2 ... 33 GND 16 INIT IN 34 N.C.*2 17 GND ... 35 +5.0V*3 18 +5.0V*4 ... 36 SELECT IN *1: All RETs are connected to GND. *2: N.C. means no connection. *3: The level is pulled up with +5.0 V through a 3.3 k resistor. *4: The level is pulled up with +5.0 V through a 390 resistor. BJC-6000 I/O IN OUT IN 2-10