HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 102
fault events. WBEM EventID: 7014. WBEM ProviderName: FPL_IndicationProvider
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
Event ID Event Severity Event Description 12399 Warning An electronic keying problem has been detected. Probable Cause: The 'e-keying error' only occurs during the power-up if the SVB must be left off due to an electronic keying problem. Recommended Action: Try installing SVB in a different location. 12400 Warning A Blade was installed in an improper location in the enclosure in violation of enclosure configuration rules. Review the installation documentation for additional information. Check the OA for additional related events. Probable Cause: SVB inserted in an improper location. Recommended Action: SVB must be installed in specific positions relative to fans or other components. WBEM EventID: 7009. WBEM ProviderName: FPL_IndicationProvider 12401 Warning A Blade was installed in the enclosure in violation of enclosure cooling configuration rules. Review the installation documentation for additional information. Check the OA for additional related events. Probable Cause: The 'cooling error' occurs during the power-up if the SVB must be left off due to insufficient cooling. Recommended Action: More fans may be needed for sufficient cooling. WBEM EventID: 7010. WBEM ProviderName: FPL_IndicationProvider 12403 Warning The sx2000 fabric reported an unexpected error. Try reseating the cell that reported the error. If assistance is required, notify the Call Center. Probable Cause: Firmware internal data corruption. Recommended Action: Reset cell that emitted the event. WBEM EventID: 7011. WBEM ProviderName: FPL_IndicationProvider 12408 Warning The OA was unable to service a power-on request. Try re-issuing the power-on request. If the problem reoccurs after subsequent requests, notify the Call Center for assistance. Probable Cause: If Onboard Administrator is busy in processing another requests, then it sends BUSY response for any requests that cannot be processed in time. Recommended Action: Try issuing the requests after some time. If the problem exists even after subsequent requests, please contact the HP representative. WBEM EventID: 7013. WBEM ProviderName: FPL_IndicationProvider 12411 Warning The IO backplane in the specified cabinet is reporting a non-redundant PCI power condition. It is possible that one of the PCI bricks is not present or not functioning properly. Check for PCI brick fault events. Probable Cause: One of the PCI bricks is not present or not functioning properly Recommended Action: Check for PCI brick fault events. WBEM EventID: 7014. WBEM ProviderName: FPL_IndicationProvider 12547 Error The migration source could not connect to the target. Probable Cause: The migration source was unable to establish a network connection to the target. The guest will continue to run on the source. Recommended Action: Check the network connection between the source and target. 12548 Error A migration has failed. Probable Cause: A migration has failed. The data indicates a failure code. Recommended Action: Verify that the source and target network has enough bandwidth and that the target has suficient resources. 12550 Warning A migration was not successful. Probable Cause: This message follows a MIGRATION_ABORTED message. Recommended Action: None. 12551 Error The virtual machine was not able to allocate memory for an I/O device. Probable Cause: Not enough memory is available. Recommended Action: Check the amount of memory in use. 12557 Warning HP unsupported DIMM(s) has been detected on this partition. Probable Cause: HP PFM service has detected one or more HP unsupported DIMMs on this partition. Recommended Action: Make sure to have HP supported DIMMs installed. 12560 Error OS run-time critical shutdown occurred. Probable Cause: The OS has caused the system to shut down. Recommended Action: Look at OS logs and crash data to determine why the system shut down. 12586 Error The amount of power expected to be drawn by the currently operating hardware is greater than the rating of the currently operating Bulk Power Supplies (BPS). Probable Cause: A bulk power supply has failed or was removed when the system had the minimal number of required bulk power supplies. Recommended Action: Replace the failed or removed bulk power supply. WBEM EventID: 7250. WBEM ProviderName: FPL_IndicationProvider 102 WBEM Provider Event Tables