to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane, IO

Page 96 highlights

Event ID Event Severity Event Description 12109 Warning An error occurred while retrieving the crossbar chip number. Probable Cause: System firmware had difficulty determining the crossbar number from the graph data structure Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 5251. WBEM ProviderName: FPL_IndicationProvider 12119 Warning One or more of the cells are not configured for Cell-Local Memory (CLM) mode. Probable Cause: The initial partition configuration may have not specified 100% Cell-Local Memory or may have been reconfigured incorrectly. Recommended Action: Reconfigure the partition or reset the CLM setting on one or more cells in your partition using the Partition Manager or ParCLI tools. WBEM EventID: 5259. WBEM ProviderName: FPL_IndicationProvider 12120 Warning Double DRAM chip sparing events have been invoked. Probable Cause: System firmware has detected and corrected memory errors. Double DRAM chip sparing events have been invoked to help mitigate this condition. On the next reboot, system firmware will test the specified memory components, and may take them offline if the errors persist. Recommended Action: Contact your HP support representative to check the specified memory. WBEM EventID: 5260. WBEM ProviderName: FPL_IndicationProvider 12121 Warning A platform error was detected by the firmware/hardware, and corrected by using a spare channel. Probable Cause: Hardware has detected many link retries on one of its channels and has switched to a spare one. Recommended Action: Monitor the situation and contact your HP support representative to check the affected hardware. WBEM EventID: 5261. WBEM ProviderName: FPL_IndicationProvider 12127 Warning A platform error was detected by the firmware/hardware, and corrected by using a spare channel. Probable Cause: The error occurred between the crossbar chips on the backplane(s). Recommended Action: Contact your support representative to have the backplane and / or connections between backplanes checked WBEM EventID: 5263. WBEM ProviderName: FPL_IndicationProvider 12128 Warning A platform error was detected by the firmware/hardware, and corrected by using a spare channel. Probable Cause: The error occurred between the cell controller and the IO controller. Recommended Action: Contact your support representative to have the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane, cell, or system backplane WBEM EventID: 5264. WBEM ProviderName: FPL_IndicationProvider 12129 Warning Multiple platform errors were detected and corrected by the firmware/hardware. Probable Cause: The errors occurred between the cell controller and the backplane. Recommended Action: Contact your support representative to have the Cell Controller to backplane Interface checked. WBEM EventID: 5265. WBEM ProviderName: FPL_IndicationProvider 12130 Warning Multiple platform errors were detected and corrected by the firmware/hardware. Probable Cause: The errors occurred between the crossbar chips on the backplane(s). Recommended Action: Contact your support representative to have the backplane and / or connections between backplanes checked. WBEM EventID: 5266. WBEM ProviderName: FPL_IndicationProvider 12131 Warning Multiple platform errors were detected and corrected by the firmware/hardware. Probable Cause: The errors occurred between the cell controller and the IO controller. Recommended Action: Contact your support representative to have the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane, cell, or system backplane. WBEM EventID: 5267. WBEM ProviderName: FPL_IndicationProvider 12132 Error The server ID does not match the cabinet type. Probable Cause: The cabinet type is not in agreement with the server identification information. The server identification information is viewable using the ID command from the MP's command menu. The cabinet type is displayed in the top line of the cabinet status shown when the PS command from the MP's command menu is used to target a compute cabinet. Recommended Action: Contact your support representative to have the server identification information and cabinet type checked. WBEM EventID: 5269. WBEM ProviderName: FPL_IndicationProvider 96 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
An error occurred while retrieving the crossbar chip number. Probable Cause: System
firmware had difficulty determining the crossbar number from the graph data
structure Recommended Action: Capture IPMI event logs, look for additional errors.
Contact your HP Support Representative to analyze the fabric WBEM EventID: 5251.
WBEM ProviderName: FPL_IndicationProvider
Warning
12109
One or more of the cells are not configured for Cell-Local Memory (CLM) mode.
Probable Cause: The initial partition configuration may have not specified 100%
Cell-Local Memory or may have been reconfigured incorrectly. Recommended Action:
Reconfigure the partition or reset the CLM setting on one or more cells in your
partition using the Partition Manager or ParCLI tools. WBEM EventID: 5259. WBEM
ProviderName: FPL_IndicationProvider
Warning
12119
Double DRAM chip sparing events have been invoked. Probable Cause: System
firmware has detected and corrected memory errors. Double DRAM chip sparing
events have been invoked to help mitigate this condition. On the next reboot, system
firmware will test the specified memory components, and may take them offline if
the errors persist. Recommended Action: Contact your HP support representative
to check the specified memory. WBEM EventID: 5260. WBEM ProviderName:
FPL_IndicationProvider
Warning
12120
A platform error was detected by the firmware/hardware, and corrected by using a
spare channel. Probable Cause: Hardware has detected many link retries on one of
its channels and has switched to a spare one. Recommended Action: Monitor the
situation and contact your HP support representative to check the affected hardware.
WBEM EventID: 5261. WBEM ProviderName: FPL_IndicationProvider
Warning
12121
A platform error was detected by the firmware/hardware, and corrected by using a
spare channel. Probable Cause: The error occurred between the crossbar chips on
the backplane(s). Recommended Action: Contact your support representative to have
the backplane and / or connections between backplanes checked WBEM EventID:
5263. WBEM ProviderName: FPL_IndicationProvider
Warning
12127
A platform error was detected by the firmware/hardware, and corrected by using a
spare channel. Probable Cause: The error occurred between the cell controller and
the IO controller. Recommended Action: Contact your support representative to have
the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable, IO
chassis, IO backplane, cell, or system backplane WBEM EventID: 5264. WBEM
ProviderName: FPL_IndicationProvider
Warning
12128
Multiple platform errors were detected and corrected by the firmware/hardware.
Probable Cause: The errors occurred between the cell controller and the backplane.
Recommended Action: Contact your support representative to have the Cell Controller
to backplane Interface checked. WBEM EventID: 5265. WBEM ProviderName:
FPL_IndicationProvider
Warning
12129
Multiple platform errors were detected and corrected by the firmware/hardware.
Probable Cause: The errors occurred between the crossbar chips on the backplane(s).
Recommended Action: Contact your support representative to have the backplane
and / or connections between backplanes checked. WBEM EventID: 5266. WBEM
ProviderName: FPL_IndicationProvider
Warning
12130
Multiple platform errors were detected and corrected by the firmware/hardware.
Probable Cause: The errors occurred between the cell controller and the IO controller.
Recommended Action: Contact your support representative to have the Cell Controller
to IO Interface checked. Check these FRUs: Cell-IO cable, IO chassis, IO backplane,
cell, or system backplane. WBEM EventID: 5267. WBEM ProviderName:
FPL_IndicationProvider
Warning
12131
The server ID does not match the cabinet type. Probable Cause: The cabinet type is
not in agreement with the server identification information. The server identification
information is viewable using the ID command from the MP's command menu. The
cabinet type is displayed in the top line of the cabinet status shown when the PS
command from the MP's command menu is used to target a compute cabinet.
Recommended Action: Contact your support representative to have the server
identification information and cabinet type checked. WBEM EventID: 5269. WBEM
ProviderName: FPL_IndicationProvider
Error
12132
96