HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 8
Hot Swap Cage: SCSI cable removed. Probable Cause: This alert indicates that a SCSI, Event Description
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Event ID Event Severity Event Description 6 Error Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors Recommended Action: Find cause of temperature anomaly and fix it. WBEM EventID: 6. WBEM ProviderName: FPL_IndicationProvider02 8 Error A measured voltage in the server has gone far outside the factory specified lower voltage range. Probable Cause: The voltage in the server has gone outside the factory set range. A bad component, blown fuse, poorly seated module, loose cable, or debris could be responsible for this failure. Recommended Action: Check all boards, power supplies, and modules that either supply or use this voltage rail. WBEM EventID: 8. WBEM ProviderName: FPL_IndicationProvider02 9 Error Voltage sensor crossed lower non-recoverable threshold. Probable Cause: The voltage in the server has gone far outside the factory set range and could damage system components. A bad component, blown fuse, poorly seated module, loose cable, or debris could be responsible for this failure. Recommended Action: Check all boards, power supplies, and modules that either supply or use this voltage rail. WBEM EventID: 9. WBEM ProviderName: FPL_IndicationProvider02 A measured voltage in the server has gone outside the factory specified upper voltage range. Probable Cause: The voltage in the server has gone outside the factory set range. A bad component, blown fuse, poorly seated module, loose cable, or debris could be responsible for this failure. Recommended Action: Check all boards, power supplies, and modules that either supply or use this voltage rail. WBEM EventID: 10 Warning 10. WBEM ProviderName: FPL_IndicationProvider02 12 Error Voltage sensor crossed upper non-recoverable threshold. Probable Cause: The voltage in the server has gone far outside the factory set range and could damage system components. A bad component, blown fuse, poorly seated module, loose cable, or debris could be responsible for this failure. Recommended Action: Check all boards, power supplies, and modules that either supply or use this voltage rail. WBEM EventID: 12. WBEM ProviderName: FPL_IndicationProvider02 The server's built-in sensors have detected an open chassis door. Probable Cause: The server has detect that the chassis door or other access panel is not securely closed. Recommended Action: Close any open panels or chassis doors. WBEM EventID: 26. 26 Warning WBEM ProviderName: FPL_IndicationProvider02 Hot Swap Cage: SCSI cable removed. Probable Cause: This alert indicates that a SCSI cable, Jumper or Duplex Connector has either been disconnected or removed. This may make some SCSI devices inaccessible. Recommended Action: Ensure that all the required SCSI cables, jumpers or duplex connectors are correctly connected to the cage, disks, and/or the controller. WBEM EventID: 113. WBEM ProviderName: 113 Warning FPL_IndicationProvider02 518 Error Uncorrectable multi-bit ECC error has occurred. Probable Cause: There has been an ECC double-bit error in one of the server's ECC memory modules. When an ECC double-bit memory error is detected, the system generates a Non-Maskable Interrupt that halts the system to prevent errors from propagating to other subsystems. Data being written or transmitted at the time may have been lost. Recommended Action: Make a note of the failed memory bank/board number and slot number, contact HP support to replace the failed module. WBEM EventID: 518. WBEM ProviderName: FPL_IndicationProvider02 8 WBEM Provider Event Tables