HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 84

Unable to write to an XBC port ROUTE_TABLE_ENABLE_MASK CSR in Arches

Page 84 highlights

Event ID Event Severity Event Description 10833 Warning Firmware error setting the NVRAM value of preferred-bsp for the vPars monitor. The partition will boot using the PD monarch, but the value of preferred-bsp may not match this CPU. Probable Cause: Firmware could not store to the NVRAM holding the EFI preferred-bsp variable Recommended Action: Reset the server, restore factory default NVRAM and reconfigure soft partitions. WBEM EventID: 4702. WBEM ProviderName: FPL_IndicationProvider 10842 Warning Unable to write to an XBC port ROUTE_TABLE_ENABLE_MASK CSR in Arches Fabric Phase3. Data field: (XBC port 48) | (XBC ID 32) | (route). Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 4704. WBEM ProviderName: FPL_IndicationProvider 10853 Error An unrecoverable processor interrupt occurred. IPF firmware owned the processor interrupt vector table (IVT) at the time of the interrupt. Probable Cause:. Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 4705. WBEM ProviderName: FPL_IndicationProvider 10871 Error SBA call to LBA SetDeviceMask method fails. Probable Cause: SBA call to LBA SetDeviceMask method fails. Recommended Action: Disable rope in non-mca path, error exit in MCA path. WBEM EventID: 4766. WBEM ProviderName: FPL_IndicationProvider 10927 Error LBA slot device scan error. Probable Cause: The LBA component detected a card in a PCI slot, but got no response from config register requests to the card. Recommended Action: Reseat or replace the PCI card. WBEM EventID: 4820. WBEM ProviderName: FPL_IndicationProvider 10936 Warning There is none (or inadequate) memory slice resource assigned to the fPar so it cannot boot its instance. The fPar will be disabled (enter a spinloop) because it cannot boot, or if in vPars mode will return control to the monitor. Probable Cause: There is no Memory owned by the soft partition (fPar) whose CPU emitted this event. Recommended Action: Reconfigure the soft partition containing the CPU that emitted this event and be sure to give memory resources to that soft partition before reset of that partition. Until doing so, this soft partition will be unbootable and emit this event on each attempt. WBEM EventID: 4708. WBEM ProviderName: FPL_IndicationProvider 10937 Warning Couldn't collect vertex information during Fabric Info call. Data Field: return status. Probable Cause: There was a problem while collecting a list of fabric link info. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4860. WBEM ProviderName: FPL_IndicationProvider 10938 Warning Couldn't collect the vertices during the Fabric Info call. Data Field: number of vertices returned. Probable Cause: An invalid number of fabric vertices was found while collecting fabric information. Recommended Action: Fabric information cannot be reported properly. Collect IPMI Event logs and contact your HP Support Representative. WBEM EventID: 4861. WBEM ProviderName: FPL_IndicationProvider 10939 Warning Couldn't find all the edges during a procedure call. Data Field: return status. Probable Cause: There was a problem while collecting a list of fabric link info. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4862. WBEM ProviderName: FPL_IndicationProvider 10940 Warning Couldn't find an appropriate number of edges during a procedure call. Data Field: the number of edges found. Probable Cause: There was a problem while collecting a list of fabric link info. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4863. WBEM ProviderName: FPL_IndicationProvider 84 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
Firmware error setting the NVRAM value of preferred-bsp for the vPars monitor.
The partition will boot using the PD monarch, but the value of preferred-bsp may
not match this CPU. Probable Cause: Firmware could not store to the NVRAM holding
the EFI preferred-bsp variable Recommended Action: Reset the server, restore factory
default NVRAM and reconfigure soft partitions. WBEM EventID: 4702. WBEM
ProviderName: FPL_IndicationProvider
Warning
10833
Unable to write to an XBC port ROUTE_TABLE_ENABLE_MASK CSR in Arches
Fabric Phase3. Data field: (XBC port 48) | (XBC ID 32) | (route). Probable Cause:
System firmware was unable to write a fabric hardware register. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric WBEM EventID: 4704. WBEM ProviderName:
FPL_IndicationProvider
Warning
10842
An unrecoverable processor interrupt occurred. IPF firmware owned the processor
interrupt vector table (IVT) at the time of the interrupt. Probable Cause:. Probable
bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The
event data field contains the IVT offset applicable to the interrupt. See table 5-7
(Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action:
Provide console log containing register dump to HP Customer Engineer. WBEM
EventID: 4705. WBEM ProviderName: FPL_IndicationProvider
Error
10853
SBA call to LBA SetDeviceMask method fails. Probable Cause: SBA call to LBA
SetDeviceMask method fails. Recommended Action: Disable rope in non-mca path,
error exit in MCA path. WBEM EventID: 4766. WBEM ProviderName:
FPL_IndicationProvider
Error
10871
LBA slot device scan error. Probable Cause: The LBA component detected a card in
a PCI slot, but got no response from config register requests to the card. Recommended
Action: Reseat or replace the PCI card. WBEM EventID: 4820. WBEM ProviderName:
FPL_IndicationProvider
Error
10927
There is none (or inadequate) memory slice resource assigned to the fPar so it cannot
boot its instance. The fPar will be disabled (enter a spinloop) because it cannot boot,
or if in vPars mode will return control to the monitor. Probable Cause: There is no
Memory owned by the soft partition (fPar) whose CPU emitted this event.
Recommended Action: Reconfigure the soft partition containing the CPU that emitted
this event and be sure to give memory resources to that soft partition before reset of
that partition. Until doing so, this soft partition will be unbootable and emit this
event on each attempt. WBEM EventID: 4708. WBEM ProviderName:
FPL_IndicationProvider
Warning
10936
Couldn't collect vertex information during Fabric Info call. Data Field: return status.
Probable Cause: There was a problem while collecting a list of fabric link info.
Recommended Action: Look for additional IPMI event logs. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 4860. WBEM ProviderName:
FPL_IndicationProvider
Warning
10937
Couldn't collect the vertices during the Fabric Info call. Data Field: number of vertices
returned. Probable Cause: An invalid number of fabric vertices was found while
collecting fabric information. Recommended Action: Fabric information cannot be
reported properly. Collect IPMI Event logs and contact your HP Support
Representative. WBEM EventID: 4861. WBEM ProviderName: FPL_IndicationProvider
Warning
10938
Couldn't find all the edges during a procedure call. Data Field: return status. Probable
Cause: There was a problem while collecting a list of fabric link info. Recommended
Action: Look for additional IPMI event logs. Contact your HP Support Representative
to analyze the fabric. WBEM EventID: 4862. WBEM ProviderName:
FPL_IndicationProvider
Warning
10939
Couldn't find an appropriate number of edges during a procedure call. Data Field:
the number of edges found. Probable Cause: There was a problem while collecting
a list of fabric link info. Recommended Action: Look for additional IPMI event logs.
Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4863.
WBEM ProviderName: FPL_IndicationProvider
Warning
10940
84
WBEM Provider Event Tables