HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 40

Waiting for the XBC Global Semaphore has timed out. Probable Cause: XBC Key

Page 40 highlights

Event ID Event Severity Event Description 7661 Warning An unexpected XBC forward progress state was continually found until timing out. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PDCheck the XBC chips seating reset the system replace either cells/system backplane WBEM EventID: 601. WBEM ProviderName: FPL_IndicationProvider 7663 Error During remote routing, the current port's neighbor is not healthy. Probable Cause: An XBC port is not healthy. Recommended Action: Check for hardware failure: flex cables, crossbar chips, etc. WBEM EventID: 602. WBEM ProviderName: FPL_IndicationProvider 7664 Error The CC to XBC link is not viable. Probable Cause: The CC to XBC link is not operational. Recommended Action: Reset the cell Reset the system backplane Contact HP Support personnel to troubleshoot problem WBEM EventID: 603. WBEM ProviderName: FPL_IndicationProvider 7666 Error Remote routing a crossbar failed. Probable Cause: A failure was encountered while performing remote routing on an XBC, most likely due to a problem with the system backplane or local cell. Recommended Action: Check for hardware failure: CC, XBC to CC link, flex cables, crossbar chip, etc. WBEM EventID: 604. WBEM ProviderName: FPL_IndicationProvider 7667 Error Too many XBC-to-XBC were broken in the complex. Probable Cause: Port status indicated that two or more ports on a XBC had errors. Recommended Action: Check for hardware failure: flex cables, crossbar chip, etc. WBEM EventID: 605. WBEM ProviderName: FPL_IndicationProvider 7669 Error This cell did not get the XBC Global Semaphore. Probable Cause: XBC write or read failure. Recommended Action: check XBC, check link, check CC WBEM EventID: 606. WBEM ProviderName: FPL_IndicationProvider 7671 Error Attempted an XBC SM4 takeover and timed out trying to unlock the SM4. Probable Cause: Cannot takeover an XBC semaphore that has been held for a long time. Recommended Action: Try forcing firmware to reroute the fabric by cycling 48V power on the cabinets. Look for other fabric chassis codes that explain why the current owner of the SM4 was unable to release it. Look for fabric problems on the backplane. WBEM EventID: 607. WBEM ProviderName: FPL_IndicationProvider 7673 Error Waiting for the XBC Global Semaphore has timed out. Probable Cause: XBC Key Contention. Hardware Failure Recommended Action: Look for other chassis codes that indicate XBC Key contention. Check XBC. Check Links/Flex Cables WBEM EventID: 608. WBEM ProviderName: FPL_IndicationProvider 7674 Error A timeout occurred while attempting to release the XBC semaphore. Probable Cause: XBC Key Contention. Hardware Failure Recommended Action: Look for additional chassis codes that would explain the failure. Check XBC. Check Link/Flex Cables WBEM EventID: 609. WBEM ProviderName: FPL_IndicationProvider 7684 Warning Management Processor Firmware Battery Failure or NVRAM change. Probable Cause: Determine if the firmware was recently upgraded. This is often the reason for the NVRAM to change. If not, and the A/C power has been removed, than it's possible the battery is indeed going bad and would need to be replaced. WBEM EventID: 610. WBEM ProviderName: FPL_IndicationProvider 7685 Warning Management Processor Firmware Software Error. Probable Cause: A software error was detected and is being logged. The internal data is connected to the location and module where the error occurred. The Forward Progress Log will receive additional (lower alert level) event entries with more data associated with this event. WBEM EventID: 611. WBEM ProviderName: FPL_IndicationProvider 40 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
An unexpected XBC forward progress state was continually found until timing out.
Probable Cause: An XBC is indicating a port failure Recommended Action: Validate
all of the cells connectivity to the PDCheck the XBC chips seating reset the system
replace either cells/system backplane WBEM EventID: 601. WBEM ProviderName:
FPL_IndicationProvider
Warning
7661
During remote routing, the current port's neighbor is not healthy. Probable Cause:
An XBC port is not healthy. Recommended Action: Check for hardware failure: flex
cables, crossbar chips, etc. WBEM EventID: 602. WBEM ProviderName:
FPL_IndicationProvider
Error
7663
The CC to XBC link is not viable. Probable Cause: The CC to XBC link is not
operational. Recommended Action: Reset the cell Reset the system backplane Contact
HP Support personnel to troubleshoot problem WBEM EventID: 603. WBEM
ProviderName: FPL_IndicationProvider
Error
7664
Remote routing a crossbar failed. Probable Cause: A failure was encountered while
performing remote routing on an XBC, most likely due to a problem with the system
backplane or local cell. Recommended Action: Check for hardware failure: CC, XBC
to CC link, flex cables, crossbar chip, etc. WBEM EventID: 604. WBEM ProviderName:
FPL_IndicationProvider
Error
7666
Too many XBC-to-XBC were broken in the complex. Probable Cause: Port status
indicated that two or more ports on a XBC had errors. Recommended Action: Check
for hardware failure: flex cables, crossbar chip, etc. WBEM EventID: 605. WBEM
ProviderName: FPL_IndicationProvider
Error
7667
This cell did not get the XBC Global Semaphore. Probable Cause: XBC write or read
failure. Recommended Action: check XBC, check link, check CC WBEM EventID:
606. WBEM ProviderName: FPL_IndicationProvider
Error
7669
Attempted an XBC SM4 takeover and timed out trying to unlock the SM4. Probable
Cause: Cannot takeover an XBC semaphore that has been held for a long time.
Recommended Action: Try forcing firmware to reroute the fabric by cycling 48V
power on the cabinets. Look for other fabric chassis codes that explain why the current
owner of the SM4 was unable to release it. Look for fabric problems on the backplane.
WBEM EventID: 607. WBEM ProviderName: FPL_IndicationProvider
Error
7671
Waiting for the XBC Global Semaphore has timed out. Probable Cause: XBC Key
Contention. Hardware Failure Recommended Action: Look for other chassis codes
that indicate XBC Key contention. Check XBC. Check Links/Flex Cables WBEM
EventID: 608. WBEM ProviderName: FPL_IndicationProvider
Error
7673
A timeout occurred while attempting to release the XBC semaphore. Probable Cause:
XBC Key Contention. Hardware Failure Recommended Action: Look for additional
chassis codes that would explain the failure. Check XBC. Check Link/Flex Cables
WBEM EventID: 609. WBEM ProviderName: FPL_IndicationProvider
Error
7674
Management Processor Firmware Battery Failure or NVRAM change. Probable Cause:
Determine if the firmware was recently upgraded. This is often the reason for the
NVRAM to change. If not, and the A/C power has been removed, than it's possible
the battery is indeed going bad and would need to be replaced. WBEM EventID: 610.
WBEM ProviderName: FPL_IndicationProvider
Warning
7684
Management Processor Firmware Software Error. Probable Cause: A software error
was detected and is being logged. The internal data is connected to the location and
module where the error occurred. The Forward Progress Log will receive additional
(lower alert level) event entries with more data associated with this event. WBEM
EventID: 611. WBEM ProviderName: FPL_IndicationProvider
Warning
7685
40
WBEM Provider Event Tables