HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 40
Waiting for the XBC Global Semaphore has timed out. Probable Cause: XBC Key
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Event ID Event Severity Event Description 7661 Warning An unexpected XBC forward progress state was continually found until timing out. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PDCheck the XBC chips seating reset the system replace either cells/system backplane WBEM EventID: 601. WBEM ProviderName: FPL_IndicationProvider 7663 Error During remote routing, the current port's neighbor is not healthy. Probable Cause: An XBC port is not healthy. Recommended Action: Check for hardware failure: flex cables, crossbar chips, etc. WBEM EventID: 602. WBEM ProviderName: FPL_IndicationProvider 7664 Error The CC to XBC link is not viable. Probable Cause: The CC to XBC link is not operational. Recommended Action: Reset the cell Reset the system backplane Contact HP Support personnel to troubleshoot problem WBEM EventID: 603. WBEM ProviderName: FPL_IndicationProvider 7666 Error Remote routing a crossbar failed. Probable Cause: A failure was encountered while performing remote routing on an XBC, most likely due to a problem with the system backplane or local cell. Recommended Action: Check for hardware failure: CC, XBC to CC link, flex cables, crossbar chip, etc. WBEM EventID: 604. WBEM ProviderName: FPL_IndicationProvider 7667 Error Too many XBC-to-XBC were broken in the complex. Probable Cause: Port status indicated that two or more ports on a XBC had errors. Recommended Action: Check for hardware failure: flex cables, crossbar chip, etc. WBEM EventID: 605. WBEM ProviderName: FPL_IndicationProvider 7669 Error This cell did not get the XBC Global Semaphore. Probable Cause: XBC write or read failure. Recommended Action: check XBC, check link, check CC WBEM EventID: 606. WBEM ProviderName: FPL_IndicationProvider 7671 Error Attempted an XBC SM4 takeover and timed out trying to unlock the SM4. Probable Cause: Cannot takeover an XBC semaphore that has been held for a long time. Recommended Action: Try forcing firmware to reroute the fabric by cycling 48V power on the cabinets. Look for other fabric chassis codes that explain why the current owner of the SM4 was unable to release it. Look for fabric problems on the backplane. WBEM EventID: 607. WBEM ProviderName: FPL_IndicationProvider 7673 Error Waiting for the XBC Global Semaphore has timed out. Probable Cause: XBC Key Contention. Hardware Failure Recommended Action: Look for other chassis codes that indicate XBC Key contention. Check XBC. Check Links/Flex Cables WBEM EventID: 608. WBEM ProviderName: FPL_IndicationProvider 7674 Error A timeout occurred while attempting to release the XBC semaphore. Probable Cause: XBC Key Contention. Hardware Failure Recommended Action: Look for additional chassis codes that would explain the failure. Check XBC. Check Link/Flex Cables WBEM EventID: 609. WBEM ProviderName: FPL_IndicationProvider 7684 Warning Management Processor Firmware Battery Failure or NVRAM change. Probable Cause: Determine if the firmware was recently upgraded. This is often the reason for the NVRAM to change. If not, and the A/C power has been removed, than it's possible the battery is indeed going bad and would need to be replaced. WBEM EventID: 610. WBEM ProviderName: FPL_IndicationProvider 7685 Warning Management Processor Firmware Software Error. Probable Cause: A software error was detected and is being logged. The internal data is connected to the location and module where the error occurred. The Forward Progress Log will receive additional (lower alert level) event entries with more data associated with this event. WBEM EventID: 611. WBEM ProviderName: FPL_IndicationProvider 40 WBEM Provider Event Tables