HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 92
Recommended Action: Update SFW. Contact your HP representative for support.
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
Event ID Event Severity Event Description 11724 Error Reboot failed. The virtual machine will exit. Probable Cause: The virtual machine was unable to restart. The next event contains the Unix error. Recommended Action: Restart if possible WBEM EventID: 5151. WBEM ProviderName: FPL_IndicationProvider 11775 Warning SetupInitialCohTables() returned an error. Data field: (cell set 32) | (return value from SetupInitialCohTables()). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4978. WBEM ProviderName: FPL_IndicationProvider 11780 Warning Stable store read or write to flash failed. Probable Cause: Soft error Flash part Failure Recommended Action: Reboot, if problem persists, contact HP support WBEM EventID: 5152. WBEM ProviderName: FPL_IndicationProvider 11783 Warning Error reading or writing the stable store NVM area. Probable Cause: A read/write to the NVM stable storage area failed Recommended Action: Reboot, if problem persists, contact HP support WBEM EventID: 5153. WBEM ProviderName: FPL_IndicationProvider 11784 Error FW has detected an illegal memory config using 4GB DIMMs. The system will be halted. Probable Cause: An unsupported memory configuration with 4GB DIMMs is installed in the system Recommended Action: Refer to the user documentation to determine the supported memory configurations with 4GB DIMMs WBEM EventID: 5154. WBEM ProviderName: FPL_IndicationProvider 11788 Warning SFW failed to allocate enough NVM to store all required data. Probable Cause: Not enough space allocated to store all required data in NVM. Recommended Action: Upgrade FW Contact HP support WBEM EventID: 6857. WBEM ProviderName: FPL_IndicationProvider 11789 Warning SFW failed to allocate enough SCR RAM to store all required data. Probable Cause: SFW component does not allocate enough space in the SCR RAM for store it data. Recommended Action: Update SFW. Contact your HP representative for support. WBEM EventID: 6858. WBEM ProviderName: FPL_IndicationProvider 11797 Warning SetupIntialCohTables() returned an error in ArfPhase3. Data field: cell set [63:32], return value [31:0]. Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5157. WBEM ProviderName: FPL_IndicationProvider 11807 Warning Error writing the error masks for ALREC and ALTRAN. Data field: cell ID [63:56], port num [55:44], XBC ID [43:32]. Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5161. WBEM ProviderName: FPL_IndicationProvider 11840 Warning Firmware had an unexpected internal error from the vertex module.. Data field: vType1 [63:56] | vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2 [15:0]. Probable Cause: An error occurred while routing the fabric, possible data corruption or firmware error. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5162. WBEM ProviderName: FPL_IndicationProvider 11850 Error The OS being booted is not supported in a partition containing a mix of processor stepping revisions. Probable Cause: The OS being booted is not supported in a partition containing a mix of processor stepping revisions. Recommended Action: Failed processors should be replaced with like processors. Reconfigure the hardware to avoid configurations with mixed steppings. WBEM EventID: 5163. WBEM ProviderName: FPL_IndicationProvider 92 WBEM Provider Event Tables