HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 36
versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Event ID Event Severity Event Description 5771 Warning Unable to enter normal system mode because EFI/SAL interface not initialized. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 512. WBEM ProviderName: FPL_IndicationProvider 5772 Error Unable to initialize part of the SAL/EFI interface. Probable Cause: Incompatible versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 513. WBEM ProviderName: FPL_IndicationProvider 5774 Error An expected tree node was not found. Probable Cause: This is a bug. Contact engineering. WBEM EventID: 515. WBEM ProviderName: FPL_IndicationProvider 5776 Warning EFI unable to modify system state to 'running'. Probable Cause: BMC non functional. Recommended Action: Contact your HP representative to check the BMC. WBEM EventID: 516. WBEM ProviderName: FPL_IndicationProvider 5777 Warning /options settings for CPUBusConfigValue aren't compatible with PAL. Probable Cause: Update the /options value to comply with the desired features and what is supported. WBEM EventID: 2433. WBEM ProviderName: FPL_IndicationProvider 5778 Warning The Get Processor Bus Dependent Configuration Features PAL call failed. Probable Cause: Contact engineering. There is a PAL compatibility problem. WBEM EventID: 518. WBEM ProviderName: FPL_IndicationProvider 5779 Warning memory DIMM pair mismatch. Probable Cause: The user installed a mismatched pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width). Recommended Action: Install memory ranks in pairs of DIMMs that are the same size and DRAM width. WBEM EventID: 519. WBEM ProviderName: FPL_IndicationProvider 5784 Error EFI unable to initialize internal library. Probable Cause: Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 520. WBEM ProviderName: FPL_IndicationProvider 5785 Error EFI unable to initialize security system. Probable Cause: BMC not responding properly. Recommended Action: Reset BMC. Contact your HP representative if problem persists. WBEM EventID: 521. WBEM ProviderName: FPL_IndicationProvider 5786 Warning EFI detected invalid internal privilege level. Probable Cause: SAL storage corrupted. Recommended Action: Reboot system. WBEM EventID: 522. WBEM ProviderName: FPL_IndicationProvider 5787 Warning EFI detected invalid privilege level when setting password. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 523. WBEM ProviderName: FPL_IndicationProvider 5788 Error EFI MDT table is bad. Probable Cause: SFW has determined that the MDT table is invalid. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 524. WBEM ProviderName: FPL_IndicationProvider 5790 Warning Processor has incompatible fixed core ratio. Probable Cause: A CPU has a fixed ratio that is incompatible with the FSB frequency set in the chipset. Recommended Action: Contact your HP representative for support. WBEM EventID: 525. WBEM ProviderName: FPL_IndicationProvider 5791 Error All processors slated for compatibility deconfiguration. Probable Cause: The user or SFW has set all CPUs to be deconfigured. Recommended Action: Look for events indicating incompatible or bad CPUs and replace them. If problem persists contact your HP representative for support. WBEM EventID: 526. WBEM ProviderName: FPL_IndicationProvider 36 WBEM Provider Event Tables