HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 36

versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem

Page 36 highlights

Event ID Event Severity Event Description 5771 Warning Unable to enter normal system mode because EFI/SAL interface not initialized. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 512. WBEM ProviderName: FPL_IndicationProvider 5772 Error Unable to initialize part of the SAL/EFI interface. Probable Cause: Incompatible versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 513. WBEM ProviderName: FPL_IndicationProvider 5774 Error An expected tree node was not found. Probable Cause: This is a bug. Contact engineering. WBEM EventID: 515. WBEM ProviderName: FPL_IndicationProvider 5776 Warning EFI unable to modify system state to 'running'. Probable Cause: BMC non functional. Recommended Action: Contact your HP representative to check the BMC. WBEM EventID: 516. WBEM ProviderName: FPL_IndicationProvider 5777 Warning /options settings for CPUBusConfigValue aren't compatible with PAL. Probable Cause: Update the /options value to comply with the desired features and what is supported. WBEM EventID: 2433. WBEM ProviderName: FPL_IndicationProvider 5778 Warning The Get Processor Bus Dependent Configuration Features PAL call failed. Probable Cause: Contact engineering. There is a PAL compatibility problem. WBEM EventID: 518. WBEM ProviderName: FPL_IndicationProvider 5779 Warning memory DIMM pair mismatch. Probable Cause: The user installed a mismatched pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width). Recommended Action: Install memory ranks in pairs of DIMMs that are the same size and DRAM width. WBEM EventID: 519. WBEM ProviderName: FPL_IndicationProvider 5784 Error EFI unable to initialize internal library. Probable Cause: Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 520. WBEM ProviderName: FPL_IndicationProvider 5785 Error EFI unable to initialize security system. Probable Cause: BMC not responding properly. Recommended Action: Reset BMC. Contact your HP representative if problem persists. WBEM EventID: 521. WBEM ProviderName: FPL_IndicationProvider 5786 Warning EFI detected invalid internal privilege level. Probable Cause: SAL storage corrupted. Recommended Action: Reboot system. WBEM EventID: 522. WBEM ProviderName: FPL_IndicationProvider 5787 Warning EFI detected invalid privilege level when setting password. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 523. WBEM ProviderName: FPL_IndicationProvider 5788 Error EFI MDT table is bad. Probable Cause: SFW has determined that the MDT table is invalid. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 524. WBEM ProviderName: FPL_IndicationProvider 5790 Warning Processor has incompatible fixed core ratio. Probable Cause: A CPU has a fixed ratio that is incompatible with the FSB frequency set in the chipset. Recommended Action: Contact your HP representative for support. WBEM EventID: 525. WBEM ProviderName: FPL_IndicationProvider 5791 Error All processors slated for compatibility deconfiguration. Probable Cause: The user or SFW has set all CPUs to be deconfigured. Recommended Action: Look for events indicating incompatible or bad CPUs and replace them. If problem persists contact your HP representative for support. WBEM EventID: 526. WBEM ProviderName: FPL_IndicationProvider 36 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
Unable to enter normal system mode because EFI/SAL interface not initialized.
Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
512. WBEM ProviderName: FPL_IndicationProvider
Warning
5771
Unable to initialize part of the SAL/EFI interface. Probable Cause: Incompatible
versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem
persists contact your HP representative for support. WBEM EventID: 513. WBEM
ProviderName: FPL_IndicationProvider
Error
5772
An expected tree node was not found. Probable Cause: This is a bug. Contact
engineering. WBEM EventID: 515. WBEM ProviderName: FPL_IndicationProvider
Error
5774
EFI unable to modify system state to 'running'. Probable Cause: BMC non functional.
Recommended Action: Contact your HP representative to check the BMC. WBEM
EventID: 516. WBEM ProviderName: FPL_IndicationProvider
Warning
5776
/options settings for CPUBusConfigValue aren't compatible with PAL. Probable
Cause: Update the /options value to comply with the desired features and what is
supported. WBEM EventID: 2433. WBEM ProviderName: FPL_IndicationProvider
Warning
5777
The Get Processor Bus Dependent Configuration Features PAL call failed. Probable
Cause: Contact engineering. There is a PAL compatibility problem. WBEM EventID:
518. WBEM ProviderName: FPL_IndicationProvider
Warning
5778
memory DIMM pair mismatch. Probable Cause: The user installed a mismatched
pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width).
Recommended Action: Install memory ranks in pairs of DIMMs that are the same
size and DRAM width. WBEM EventID: 519. WBEM ProviderName:
FPL_IndicationProvider
Warning
5779
EFI unable to initialize internal library. Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 520. WBEM ProviderName: FPL_IndicationProvider
Error
5784
EFI unable to initialize security system. Probable Cause: BMC not responding
properly. Recommended Action: Reset BMC. Contact your HP representative if
problem persists. WBEM EventID: 521. WBEM ProviderName:
FPL_IndicationProvider
Error
5785
EFI detected invalid internal privilege level. Probable Cause: SAL storage corrupted.
Recommended Action: Reboot system. WBEM EventID: 522. WBEM ProviderName:
FPL_IndicationProvider
Warning
5786
EFI detected invalid privilege level when setting password. Probable Cause: Internal
EFI error. Recommended Action: Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem. WBEM EventID: 523. WBEM
ProviderName: FPL_IndicationProvider
Warning
5787
EFI MDT table is bad. Probable Cause: SFW has determined that the MDT table is
invalid. Recommended Action: Reboot or update System FW. If problem persists
contact your HP representative for support. WBEM EventID: 524. WBEM
ProviderName: FPL_IndicationProvider
Error
5788
Processor has incompatible fixed core ratio. Probable Cause: A CPU has a fixed ratio
that is incompatible with the FSB frequency set in the chipset. Recommended Action:
Contact your HP representative for support. WBEM EventID: 525. WBEM
ProviderName: FPL_IndicationProvider
Warning
5790
All processors slated for compatibility deconfiguration. Probable Cause: The user or
SFW has set all CPUs to be deconfigured. Recommended Action: Look for events
indicating incompatible or bad CPUs and replace them. If problem persists contact
your HP representative for support. WBEM EventID: 526. WBEM ProviderName:
FPL_IndicationProvider
Error
5791
36