HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 48
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Event ID Event Severity Event Description 8132 Warning An unknown error has been detected by the PDHC firmware. Probable Cause: Hardware in unknown state, or programming bug found. Recommended Action: Recommended Action: Upgrade PDHC firmware to latest revision. If already at current revision, contact HP support personnel to troubleshoot the problem. WBEM EventID: 627. WBEM ProviderName: FPL_IndicationProvider 8133 Warning An attempt to write to a device on the PDHCs I2C bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM EventID: 628. WBEM ProviderName: FPL_IndicationProvider 8134 Warning An attempt to read from a device on the PDHC's I2C bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM EventID: 629. WBEM ProviderName: FPL_IndicationProvider 8135 Warning An attempt to write to a device on the PDHC's SM bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM EventID: 630. WBEM ProviderName: FPL_IndicationProvider 8136 Warning An attempt to read from a device on the PDHC's SM bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and PDH Daughtercard. WBEM EventID: 631. WBEM ProviderName: FPL_IndicationProvider 8137 Error Cell boot has been disabled due to a failure setting the frequency registers. Probable Cause: Invalid data programmed in the Cell's FRU EEPROM or a CPU module's Scratch/FRU EEPROM. Recommended Action: If in manufacturing, program correct data in partition specific field of the Cell or CPU Module's FRU EEPROM. Otherwise, contact HP support personnel to troubleshoot the problem. WBEM EventID: 632. WBEM ProviderName: FPL_IndicationProvider 8138 Warning An error has occurred while updating System FW. Probable Cause: Other error indicated by FWUU. Recommended Action: Exit from FWUU, reset the MP using the XD command, then attempt to update Sytem FW. If repeated attempts to update the System FW fail, contact HP support personnel to troubleshoot the problem. WBEM EventID: 633. WBEM ProviderName: FPL_IndicationProvider 8139 Warning The PDHC firmware was reset for some unknown reason. Probable Cause: A PDHC watchdog timer timeout has occurred because the PDHC was stuck in some unknown state. Recommended Action: Upgrade PDHC firmware to the latest revision. If the error continues, contact HP support personnel to troubleshoot the PDH Daughtercard and/or Cell Board. WBEM EventID: 634. WBEM ProviderName: FPL_IndicationProvider 8140 Error Cell boot has been disabled because setup of a CPU thermal sensor failed. Probable Cause: A hardware fault exists in the communication path to a CPU module's thermal sensor, or in the thermal sensor itself. Recommended Action: Contact HP support personnel to troubleshoot the Cell Board, the PDH Daughtercard, and/or the offending CPU module. WBEM EventID: 635. WBEM ProviderName: FPL_IndicationProvider 8141 Error A CPU module has reported overtemp, so will be powered off in 1 minute. Probable Cause: Excessive heat in the data center has caused the CPU module to heat up beyond the programmed temperature threshold. Recommended Action: Resolve the environmental problem, shut down the partition, then PE the Cell off, then on again. WBEM EventID: 636. WBEM ProviderName: FPL_IndicationProvider 8143 Warning An error occurred while updating the PDHC firmware. Probable Cause: Other error indicated by Firmware Update. Recommended Action: Exit from Firmware Update, reset the MP using the XD command, then attempt to update PDHC firmware again. If repeated attempts to update the PDHC firmware fail, contact HP support personnel to troubleshoot the problem WBEM EventID: 637. WBEM ProviderName: FPL_IndicationProvider 48 WBEM Provider Event Tables