Memory Error Information not cleared. Probable Cause: Software Error or CEC error
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Event ID Event Severity Event Description 5180 Warning Memory ECC multiple-bit data error detection failed. Probable Cause: The CEC failed MBE detection. Recommended Action: Contact HP support personnel to troubleshoot the problem WBEM EventID: 307. WBEM ProviderName: FPL_IndicationProvider 5181 Warning Memory ECC multiple-bit ECC error signalling failed. Probable Cause: The CEC failed MBE detection. Recommended Action: Contact HP support personnel to troubleshoot the problem WBEM EventID: 308. WBEM ProviderName: FPL_IndicationProvider 5182 Warning Memory ECC single-bit data error detection failed. Probable Cause: The CEC failed SBE detection. Recommended Action: Contact HP support personnel to troubleshoot the problem WBEM EventID: 309. WBEM ProviderName: FPL_IndicationProvider 5183 Warning Memory ECC single-bit ECC error detection failed. Probable Cause: The CEC failed SBE detection. Recommended Action: Contact HP support personnel to troubleshoot the problem WBEM EventID: 310. WBEM ProviderName: FPL_IndicationProvider 5185 Warning Insufficient memory for operation. Probable Cause: FW detected memory errors below 1MB. Recommended Action: No action is needed if FW recovers. If system will not boot, contact HP support to troubleshoot the problem. WBEM EventID: 311. WBEM ProviderName: FPL_IndicationProvider 5186 Warning Memory address not found in MBAT. Probable Cause: The address logged in the CEC doesn't map to a memory rank, possibly due to a SFW error or NVM corruption Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 312. WBEM ProviderName: FPL_IndicationProvider 5187 Warning Memory Error Information not cleared. Probable Cause: Software Error or CEC error Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 313. WBEM ProviderName: FPL_IndicationProvider 5189 Warning Couldn't clear memory error logs. Probable Cause: SFW Error or CEC error Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 314. WBEM ProviderName: FPL_IndicationProvider 5190 Warning Memory error clear failed. Probable Cause: SFW error or CEC error Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 315. WBEM ProviderName: FPL_IndicationProvider 5191 Warning DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM is not loaded in order to allow for proper operation of the DIMM specified in the physical location. Recommended Action: Refer to the user's manual for Memory loading instructions. WBEM EventID: 316. WBEM ProviderName: FPL_IndicationProvider 5193 Warning Generic memory firmware error. Probable Cause: Corrupt NVM or System firmware failure Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 317. WBEM ProviderName: FPL_IndicationProvider 5199 Error Memory interleaving algorithm failed. Probable Cause: Unspecified WBEM EventID: 2903. WBEM ProviderName: FPL_IndicationProvider 5202 Error Memory interleave generation failed. Probable Cause: SFW is outdated. Recommended Action: Update SFW. WBEM EventID: 318. WBEM ProviderName: FPL_IndicationProvider 5204 Warning Uncorrectable (multiple-bit) ECC error in DIMM. Probable Cause: Multiple bit error in DIMM Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 2451. WBEM ProviderName: FPL_IndicationProvider 5205 Warning Memory register test failed. Probable Cause: The register within the chipset went bad. Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 319. WBEM ProviderName: FPL_IndicationProvider 5208 Error SPD found no memory DIMMs. Probable Cause: No DIMMs were detected Recommended Action: Install DIMMs or Contact HP Support personnel to troubleshoot the problem WBEM EventID: 320. WBEM ProviderName: FPL_IndicationProvider 20 WBEM Provider Event Tables