HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 86
has reported a fault. Recommended Action: Check RCS assembly. WBEM EventID
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
Event ID Event Severity Event Description 11040 Warning An error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return status. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4873. WBEM ProviderName: FPL_IndicationProvider 11041 Warning An invalid port number was returned when selecting a route for the XBC-CC link. Data Field: (destination cell 56) | (xbc port 44) | (xbc # 32) | port selected. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. 11042 Warning An error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | switch fabric. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4875. WBEM ProviderName: FPL_IndicationProvider 11052 Warning The second flash part is not programmed with a valid image. WBEM EventID: 7212. WBEM ProviderName: FPL_IndicationProvider 11452 Error System backplane power has reported a 1.2v LDO fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 1.2v LDO fault. Recommended Action: Check system backplane. WBEM EventID: 4906. WBEM ProviderName: FPL_IndicationProvider 11454 Error System backplane power has reported a 2.5v LDO fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 2.5v LDO fault. Recommended Action: Check system backplane. WBEM EventID: 4907. WBEM ProviderName: FPL_IndicationProvider 11456 Error System backplane power has reported a 3.3v house keeping power fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 3.3v house keeping fault. Recommended Action: Check system backplane power board. WBEM EventID: 4908. WBEM ProviderName: FPL_IndicationProvider 11459 Error System backplane power has reported a 12v power fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 12v fault. Recommended Action: Check system backplane power board. WBEM EventID: 4909. WBEM ProviderName: FPL_IndicationProvider 11461 Error System backplane power has reported a 3.3v power fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 3.3v fault. Recommended Action: Check system backplane power board. WBEM EventID: 4910. WBEM ProviderName: FPL_IndicationProvider 11463 Error System backplane power has reported a 1.5v power fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 1.5v fault. Recommended Action: Check system backplane power board. WBEM EventID: 4911. WBEM ProviderName: FPL_IndicationProvider 11465 Error System backplane power has reported a 2.5v power fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 2.5v fault. Recommended Action: Check system backplane power board. WBEM EventID: 4912. WBEM ProviderName: FPL_IndicationProvider 11467 Error One or more power rails is providing insufficient power to the backplane. Probable Cause: There has been multiple faults on the same power rail. Recommended Action: look for additional events describing action to take. WBEM EventID: 4913. WBEM ProviderName: FPL_IndicationProvider 11468 Error Clock fault for clocks supplied from the Redundant Clock Source (RCS) board to the system backplane. RCS board is no longer providing clocks to the backplane. The data field contains the physical location of the RCS. Probable Cause: RCS assembly has reported a fault. Recommended Action: Check RCS assembly. WBEM EventID: 4914. WBEM ProviderName: FPL_IndicationProvider 86 WBEM Provider Event Tables