HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 63
Attempt to update Cell Static Routing has failed. Probable Cause: Fabric Access Error
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Event ID Event Severity Event Description 9432 Warning Error clearing the init packet received bit in the XIN error mask. Probable Cause: CC access failure. Recommended Action: PDC Reviewed alert level for SR - 9/6/03 CC. WBEM EventID: 938. WBEM ProviderName: FPL_IndicationProvider 9433 Warning Failed to read the XBC's Port Status register. Probable Cause: fabric access failure Recommended Action: Check XBC, Check CC, Check backplane WBEM EventID: 939. WBEM ProviderName: FPL_IndicationProvider 9438 Warning PDHC has detected the PDH battery low warning. Probable Cause: PDH battery power is low. Recommended Action: Replaced the PDH battery. WBEM EventID: 1037. WBEM ProviderName: FPL_IndicationProvider 9440 Error FW will not handoff to the OS_MCA handler for this MCA event. Probable Cause: The error logs should be retrieved from the EFI shell prompt. WBEM EventID: 941. WBEM ProviderName: FPL_IndicationProvider 9441 Error Resetting the partition because couldn't access PDH memory. Probable Cause: CPU is on unreachable cell Defective CPU Recommended Action: Contact HP Support personnel to troubleshoot cell board Investigate for fabric problem WBEM EventID: 1766. WBEM ProviderName: FPL_IndicationProvider 9442 Error Resetting the partition because a processor was not in expected state. Probable Cause: Software has not correctly returned all CPUs to sleep state Recommended Action: Reset would clear this issue WBEM EventID: 1767. WBEM ProviderName: FPL_IndicationProvider 9445 Warning Halting the cell because a cell couldn't access its own PDH memory. Probable Cause: Hardware problem with the CPU or cell board. Recommended Action: Contact HP Support to confirm the CPUs and cell board are functioning properly. WBEM EventID: 1768. WBEM ProviderName: FPL_IndicationProvider 9448 Error The NVRAM block table maintained by System Firmware is corrupt. Probable Cause: The NVRAM-based descriptor for System Firmware NVRAM blocks is corrupt. WBEM EventID: 942. WBEM ProviderName: FPL_IndicationProvider 9450 Warning Resetting cell because processor couldn't access it's own PDH memory. Probable Cause: PDC bug. Recommended Action: Contact HP Support to check for PDC upgrade. WBEM EventID: 1769. WBEM ProviderName: FPL_IndicationProvider 9460 Warning All CPUs were deconfigured and have now been reconfigured. Probable Cause: User test operational error. Recommended Action: Reboot system and update CPU configuration as desired. WBEM EventID: 943. WBEM ProviderName: FPL_IndicationProvider 9461 Warning A failure has occurred trying to get the number of CPU cores per module. Probable Cause: Hardware failure with CPU, CC or cell board. Recommended Action: Contact HP Support to confirm the CPUs, CC, and cell board are functioning properly. Update PDC if a version is available to fix this problem. WBEM EventID: 944. WBEM ProviderName: FPL_IndicationProvider 9465 Warning Couldn't read the topology from the XBC register. Probable Cause: Fabric Access Error Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC WBEM EventID: 945. WBEM ProviderName: FPL_IndicationProvider 9466 Error Attempt to update Cell Static Routing has failed. Probable Cause: Fabric Access Error Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 1776. WBEM ProviderName: FPL_IndicationProvider 9468 Warning Failed to read the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 947. WBEM ProviderName: FPL_IndicationProvider 9469 Warning Failed to read the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure Recommended Action: Contact HP Support personnel to check XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM EventID: 948. WBEM ProviderName: FPL_IndicationProvider Platform Events 63