HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 38
Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Event ID Event Severity Event Description 5809 Error The XBC neighbor chip number does not match the expected value for this topology. Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. WBEM EventID: 542. WBEM ProviderName: FPL_IndicationProvider 5810 Error The XBC neighbor port number does not match the expected value for this topology. Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. WBEM EventID: 543. WBEM ProviderName: FPL_IndicationProvider 5811 Warning Write through to BMC token failed. Probable Cause: Problem accessing the BMC. Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If problem persists, contact your HP representative for support. WBEM EventID: 544. WBEM ProviderName: FPL_IndicationProvider 5812 Warning Utilities reported an error while trying to manipulate the LED. Probable Cause: It is likely the GSP is not present or the device specified is not present. Solve these problems and try again. WBEM EventID: 2465. WBEM ProviderName: FPL_IndicationProvider 5813 Error Duplicate Cpu Ids were detected within a cell. Probable Cause: Most likely cause is a bad cpu module connection on the cell board. Replace the cell board. WBEM EventID: 546. WBEM ProviderName: FPL_IndicationProvider 5823 Warning OS crashdump started (D700). Probable Cause: panic occurred WBEM EventID: 547. WBEM ProviderName: FPL_IndicationProvider 5824 Error OS legacy PA hex fault code (Bxxx). Probable Cause: fault/panic WBEM EventID: 548. WBEM ProviderName: FPL_IndicationProvider 5825 Warning OS dump status (EFxx). Probable Cause: panic, mca, or INIT path: attempt to write out the dump is complete Recommended Action: No action required WBEM EventID: 549. WBEM ProviderName: FPL_IndicationProvider 5827 Warning Setting processor response timeout failed. Probable Cause: A PAL call made by SFW has failed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 550. WBEM ProviderName: FPL_IndicationProvider 5832 Warning Unable to validate blank password during EFI security initialization. Probable Cause: BMC failed. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP representative to check the BMC. WBEM EventID: 551. WBEM ProviderName: FPL_IndicationProvider 5833 Warning Unable to enter Guest mode during EFI security initialization. Probable Cause: BMC failure. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP representative to check the BMC. WBEM EventID: 552. WBEM ProviderName: FPL_IndicationProvider 5834 Warning Unable to increase privilege during EFI security initialization. Probable Cause: SAL failure. Recommended Action: Reset the system. Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 553. WBEM ProviderName: FPL_IndicationProvider 5836 Warning EFI unable to write privilege level during security initialization. Probable Cause: SAL failure. Recommended Action: Reboot the system. Update SFW. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 554. WBEM ProviderName: FPL_IndicationProvider 5837 Warning EFI was denied permission to write the privilege level during security init. Probable Cause: SAL is not in ADMIN or USER mode. Recommended Action: Reboot the system. Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 555. WBEM ProviderName: FPL_IndicationProvider 5853 Warning OS dump, error writing image area to disk (E055). Probable Cause: panic path forward progress WBEM EventID: 556. WBEM ProviderName: FPL_IndicationProvider 38 WBEM Provider Event Tables