HP Integrity rx8620 HP Insight Manager WBEM Provider Events Reference - Page 56
Probable Cause: The System Flash Write Enable bit is incorrectly set by hardware
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Event ID Event Severity Event Description 8851 Warning The System Flash Write Enable bit is incorrectly set and now clearing by PDC. Probable Cause: The System Flash Write Enable bit is incorrectly set by hardware and now cleared by PDC. Recommended Action: If this chassis code occurs in every boot then contact HP Support personnel to troubleshoot the problem. WBEM EventID: 1764. WBEM ProviderName: FPL_IndicationProvider 8855 Error Firmware encountered a problem trying to initialize. Probable Cause: Examine the related event that failed and correct that problem. WBEM EventID: 837. WBEM ProviderName: FPL_IndicationProvider 8857 Warning This means that all the cpus in the cell did not show up. Probable Cause: This will result in the cell stepping independently to collect its logs and resting itself. WBEM EventID: 838. WBEM ProviderName: FPL_IndicationProvider 8858 Warning This means that all the cells did not rendezvous during the PD rendezvous. Probable Cause: The cells will reset themselves. WBEM EventID: 839. WBEM ProviderName: FPL_IndicationProvider 8859 Warning The FW tree sanity check failed during the MCA error processing. Probable Cause: The cells will independently log errors and reset. WBEM EventID: 840. WBEM ProviderName: FPL_IndicationProvider 8860 Warning This means that the registry sanity check failed during MCA error handling. Probable Cause: The cells will independently log errors and reset. WBEM EventID: 841. WBEM ProviderName: FPL_IndicationProvider 8861 Warning This means that MCA occurred while OS_MCA was performing error recovery. Probable Cause: The cells will log information and reset. WBEM EventID: 842. WBEM ProviderName: FPL_IndicationProvider 8864 Warning One of the BT errors occurred that results in abandoning memory dump. Probable Cause: A machine check has occurred and cells have not rendezvoused. Recommended Action: Cells will reset themselves. WBEM EventID: 843. WBEM ProviderName: FPL_IndicationProvider 8865 Warning The firmware tree is not complete and hence there will be no PD rendezvous. Probable Cause: The cell will log errors and reset WBEM EventID: 844. WBEM ProviderName: FPL_IndicationProvider 8872 Error ACPI configuration mismatch across cells in the partition. Probable Cause: Set the ACPI configuration parameter again to ensure that all cells have a consistent value. WBEM EventID: 845. WBEM ProviderName: FPL_IndicationProvider 8873 Error Failed clearing of the XIN_ERR_ORDER_STATUS CSR. Probable Cause: Failure to access the register or the write did not work. Recommended Action: Contact HP Support personnel to check the CC. WBEM EventID: 846. WBEM ProviderName: FPL_IndicationProvider 8876 Warning Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred. Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 848. WBEM ProviderName: FPL_IndicationProvider 8877 Warning Invalid data read from a CPU module's Processor Information ROM. Probable Cause: The CPU module's Processor Information ROM is unprogrammed. Recommended Action: Contact HP support personnel to troubleshoot the CPU module pointed to by the physical location portion of this event. WBEM EventID: 849. WBEM ProviderName: FPL_IndicationProvider 8882 Warning Invalid parameter when setting cpu frequency ratios. Probable Cause: Specify a valid parameter. WBEM EventID: 2444. WBEM ProviderName: FPL_IndicationProvider 8883 Warning Option block in nvram has a checksum error. Probable Cause: Clear NVRAM. WBEM EventID: 851. WBEM ProviderName: FPL_IndicationProvider 8894 Warning CC to CC link did not initialize on the local cell. Probable Cause: link failure between the XBC and the CC Recommended Action: Check CC. WBEM EventID: 852. WBEM ProviderName: FPL_IndicationProvider 56 WBEM Provider Event Tables