Event ID Event Severity Event Description 5700 Error The computed checksum for ESI Table incorrect. Probable Cause: Table corrupted. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 456. WBEM ProviderName: FPL_IndicationProvider 5701 Warning ESI Table contains an unsupported entry type. Probable Cause: Corrupted table. Recommended Action: Reboot system. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 457. WBEM ProviderName: FPL_IndicationProvider 5704 Warning A GUID was larger than the expected 128 bits. Probable Cause: Inconsistency in EFI firmware. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 458. WBEM ProviderName: FPL_IndicationProvider 5708 Error EFI is halting. Probable Cause: Unknown. Recommended Action: examine preceding events for problem. WBEM EventID: 459. WBEM ProviderName: FPL_IndicationProvider 5711 Warning chipspare not supported on quad. Probable Cause: User installed a x8 DIMM in a system configured for chipspare. Recommended Action: If user requires Chipspare, replace the DIMM with a x4 DIMM. If Chipspare is not required, then no action is required. WBEM EventID: 460. WBEM ProviderName: FPL_IndicationProvider 5712 Warning EFI internal error detected resulting in execution of ASSERT macro. Probable Cause: The cause is unknown. Recommended Action: Look at previous events and ASCII information in this event for more information. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 461. WBEM ProviderName: FPL_IndicationProvider 5713 Error EFI has executed the 'break' shell command. Probable Cause: Executing the 'break' command. Recommended Action: Check for user entering 'break' command. Check for shell scripts using the 'break' command. WBEM EventID: 462. WBEM ProviderName: FPL_IndicationProvider 5714 Error EFI USB HCD interrupt service has detected the host controller is hung. Probable Cause: Problem with USB controller. Recommended Action: Reset the card containing the USB interface to restart the controller. Contact your HP representative to check the USB interface. WBEM EventID: 463. WBEM ProviderName: FPL_IndicationProvider 5715 Error The EFI/SAL handoff structure's version does not match EFI expectations. Probable Cause: EFI/SAL firmware mismatch. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 464. WBEM ProviderName: FPL_IndicationProvider 5717 Error Unable to obtain access to all RTC SAL services. Probable Cause: Not all expected services are available. Mismatch between EFI and SAL versions. Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 465. WBEM ProviderName: FPL_IndicationProvider 5718 Error Unable to obtain access to all SAL timer services. Probable Cause: Not all expected services are available. Mismatch between EFI and SAL versions. Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 466. WBEM ProviderName: FPL_IndicationProvider 5719 Error EFI unable to start the periodic timer. Probable Cause: Internal system firmware error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 467. WBEM ProviderName: FPL_IndicationProvider 5720 Error No I/O port space region found in the MDT. Probable Cause: EFI/SAL handoff structure corrupted. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 468. WBEM ProviderName: FPL_IndicationProvider 5721 Error EFI reached an unimplemented section of code. Probable Cause: Reached unimplemented firmware. Recommended Action: Upgrade system firmware. WBEM EventID: 469. WBEM ProviderName: FPL_IndicationProvider 32 WBEM Provider Event Tables