I/O SBA clear error failed. Probable Cause: I/O chipset failure. Recommended Action
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Event ID Event Severity Event Description 5136 Warning I/O host bridge inaccessible because rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended Action: Contact your HP representative to check the I/O CEC. WBEM EventID: 276. WBEM ProviderName: FPL_IndicationProvider 5137 Warning Insufficient power to turn on PCI slot. Probable Cause: The power budget for the IO subsystem has been exceeded. Recommended Action: The IO config in the system is unsupported. Verify that the IO config installed in the system is one that is supported. If problem persists contact your HP representative for support. WBEM EventID: 277. WBEM ProviderName: FPL_IndicationProvider 5138 Warning PCI bus walk unknown error. Probable Cause: Internal firmware error. Recommended Action: Contact your HP representative to check the firmware. WBEM EventID: 278. WBEM ProviderName: FPL_IndicationProvider 5139 Warning PCI bus walk resources exceeded. Probable Cause: Unsupported I/O configuration. Recommended Action: Remove any unsupported I/O cards. Move the I/O card to another slot. WBEM EventID: 279. WBEM ProviderName: FPL_IndicationProvider 5140 Warning PCI bus unmap unknown error. Probable Cause: Internal firmware error. Recommended Action: Contact your HP representative to check the firmware. WBEM EventID: 280. WBEM ProviderName: FPL_IndicationProvider 5141 Warning PCIXCAP sampling error. Probable Cause: I/O host bridge failure. Recommended Action: Contact your HP representative to check the I/O host bridge. WBEM EventID: 281. WBEM ProviderName: FPL_IndicationProvider 5142 Warning Power monitor failed to respond. Probable Cause: BMC failure. Recommended Action: Contact your HP representative to check the BMC. WBEM EventID: 282. WBEM ProviderName: FPL_IndicationProvider 5143 Warning I/O rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended Action: Reboot. If problem persists, contact your HP representative to check the I/O controller. WBEM EventID: 283. WBEM ProviderName: FPL_IndicationProvider 5144 Warning I/O SBA clear error failed. Probable Cause: I/O chipset failure. Recommended Action: Contact your HP representative to check the I/O chipset. WBEM EventID: 284. WBEM ProviderName: FPL_IndicationProvider 5145 Warning PCI slot has incorrect default power state. Probable Cause: The hot-plug controller has failed. Recommended Action: Contact your HP representative to check the hot-plug slot. WBEM EventID: 285. WBEM ProviderName: FPL_IndicationProvider 5146 Warning PCI slot power on error. Probable Cause: The I/O card is damaged or improperly inserted. Recommended Action: Replace or reseat the I/O card. WBEM EventID: 286. WBEM ProviderName: FPL_IndicationProvider 5147 Warning PCI slot's standby power failed. Probable Cause: I/O slot failure. Recommended Action: Reseat IO card. Replace IO card. If problem persists, contact your HP representative to check the I/O slot. WBEM EventID: 287. WBEM ProviderName: FPL_IndicationProvider 5148 Warning Found invalid PCIXCAP value. Probable Cause: The I/O card is damaged or improperly inserted. Recommended Action: Replace or reseat the I/O card. WBEM EventID: 288. WBEM ProviderName: FPL_IndicationProvider 5149 Warning Unsupported rope frequency. Probable Cause: Internal firmware error. Recommended Action: Contact your HP representative to check the firmware. WBEM EventID: 289. WBEM ProviderName: FPL_IndicationProvider 5150 Warning Unsupported host bridge type. Probable Cause: Firmware needs to be updated. An incorrect I/O backplane is installed. Recommended Action: Contact your HP representative to check the firmware and the I/O backplane. WBEM EventID: 290. WBEM ProviderName: FPL_IndicationProvider 5152 Error Machine Check initiated. Probable Cause: A Machine Check has occurred. Recommended Action: Analyze cause of Machine Check using diag's and EFI tools. WBEM EventID: 292. WBEM ProviderName: FPL_IndicationProvider 18 WBEM Provider Event Tables