HP Surestore 80fx Optical Drive and Library SCSI-2 Command Reference - Page 221
Hardware Error, FRU 1, Test Number, Parameters, Table 3-30, Receive Diagnostic Results Command CDB
View all HP Surestore 80fx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 221 highlights
Table 3-30 Jukebox SCSI-2 Command Set Receive Diagnostic Results Command (1CH) Receive Diagnostic Results Command CDB Byte 7 6 5 4 3 2 1 0 0 Reserved (0) 1 Hardware Error Code 2 FRU 1 3 FRU 2 4 FRU 3 5 Number of the Test that Failed 6-13 Parameters Hardware Error Code Code is generated only if an unrecoverable error occurs (See Table B-7 on page B-19). FRU 1 The FRU most likely to be at fault (See Table C-1 on page C-2 or Table C-2 on page C-4). FRU 2 The second most likely FRU to be at fault. (See Table C-1 on page C-2 or Table C-2 on page C-4). FRU 3 The third most likely FRU to be at fault (See Table C-1 on page C-2 or Table C-2 on page C-4). Test Number The diagnostic test number. This will not be a sequence number, but the specific test that failed. Refer to Table B-12 on page B-40 for a list of the jukebox diagnostic tests. Parameters Additional parameters as defined for individual tests. There may be several like components in a unit. These components may have a common FRU number. When it is possible to detect which of these FRUs may be at fault, the error code field reflects the one to check. 3-34 Chapter 3