JVC GY-DV500U GY-DV500 User Manual - PDF (4,089KB) - Page 22

Counter Display Contents

Page 22 highlights

2. CONTROLS, INDICATORS AND CONNECTORS 2-6 Counter Display Contents OPERATE/WARNING RESET MONITOR SELECT CH 1 CH 2 40 30 20 32k 48k AUD LOCK SP MENU REMAIN H OVER AUTO OFF DEW 10 0 dB OVER SERVO RF L i PB NDF HOLD H M S F REV FWD E BATT F M LIGHT ON OFF COUNTER CTL TC UB COUNTER switch Counter display 1. Tape counter display CTL TC UB "TC" CTL TC UB "CTL" "TC" CTL TC "UB" VCR Setup UB Menu No. 516 DISPLAY SELECT CTL TC "TC" UB "CLOCK" CTL TC UB "UB" H M S H M S Hour Min Sec H M S CTL counter F Time code F User's bit Time display Date display Month Day Year 2. VCR Setup Menu display 4. Error code display 3. Hour meter display H 4. Alarm display Remaining Tape Time Display This display shows the remaining tape time (minutes/seconds) in record and play modes. • Example: 30 minutes of remaining tape. REMAIN H M • This indicator blinks when remaining tape time is equivalent to less than 2 minutes. * An alarm sounds as a warning when remaining tape time is equivalent to less than 2 minutes in the record mode REMAIN H M • The following display appears when no videocassette is loaded or during the calculation of remaining tape that takes place immediately after a videocassette is inserted. REMAIN H M 22 The counter display shows the following 4 types of information. 1. Tape counter display The counter display usually functions as a tape counter (hour, minute, second, frame). It can be switched to a CTL counter, time code or user's bit display by using the COUNTER switch. (When the VCR Setup Menu item No. 516 DISPLAY SELECT is set to "TC".) • CTL counter: Time between -9 hr. 59 min. 59 sec. 29 frames and 9 hr. 59 min. 59 sec. 29 frames can be displayed. Running mode is fixed as non-drop frame. * CTL counter indication may also corrupt at playback of segment which time code signal is not continuously recorded. • Time code : Time between 0 hour and 23 hr. 59 min. 59 sec. 29 frames can be displayed. • User's bit : Hexadecimal number from 0 to F is displayed in 8 digits. When the VCR Setup Menu item No. 516 DISPLAY SELECT is set to "CLOCK", the date and time are displayed. Set the COUNTER switch to TC or UB. TC: Time (Hour, Min., Sec.) is displayed. UB: Date (Month, Day, Year) is displayed. • Press the MENU button to switch to the VCR Setup Menu setting display. 2. VCR Setup Menu setting display This display is used when setting the setup menus. After setting of the setup menus, the tape counter display returns. For details, see "DISPLAYING AND SETTING VCR SETUP MENUS" on page 67. 3. Hour meter display The hour meter is displayed by selecting the HM group from the VCR Setup Menu. The hour meter data refers to the accumulated head drum running time. 4. Error code/Alarm display The error code or alarm indicator is displayed automatically in case an abnormal condition occurs with the unit.  See "TROUBLES WITH ERROR CODE OUTPUTS" on page 90.  See "ALARM INDICATIONS" on page 86. Remaining Battery Power Display The 7-dot segment bar display shows the remaining battery power. The lighted segment bars decrease as the remaining battery power decreases. • To display the remaining battery power accurately, set the VCR Setup Menu item No. 396 BATTERY TYPE according to the type of the battery pack in use. E BATT F All segment bars light when a fully charged battery pack is attached. E BATT The last 2 segment bars and "BATT" start to blink when the battery is nearly exhausted. Replace with a fully charged battery pack. E BATT When the battery capacity has run out, "E" and "BATT" blink and the unit stops operation automatically.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

22
2. CONTROLS, INDICATORS AND CONNECTORS
Remaining Tape Time Display
This display shows the remaining tape time (minutes/seconds)
in record and play modes.
• Example: 30 minutes of remaining tape.
This indicator blinks when remaining tape time is equivalent
to less than 2 minutes.
*
An alarm sounds as a warning when remaining tape time is
equivalent to less than 2 minutes in the record mode
The following display appears when no videocassette is
loaded or during the calculation of remaining tape that takes
place immediately after a videocassette is inserted.
E
F
BATT
E
BATT
E
BATT
H
M
REMAIN
H
M
REMAIN
H
M
REMAIN
2-6
Counter Display Contents
CTL counter
Time code
User’s bit
Time display
Date display
Hour
Min
Sec
Month
Day
Year
2.
4.
4.
H
3.
H
M
S
F
1.
CTL
TC
UB
H
M
S
F
CTL
TC
UB
CTL
TC
UB
H
M
S
CTL
TC
UB
CTL
TC
“CTL”
“TC”
“TC”
“CLOCK”
“UB”
“TC”
“UB”
UB
LIGHT
ON
OFF
COUNTER
CTL
TC
UB
RESET
OPERATE/WARNING
MONITOR
SELECT
E
REV
FWD
F
BATT
H
H
M
M
S
F
REMAIN
AUD LOCK
32k
CH 1
CH 2
48k
PB
NDF
AUTO OFF
DEW
L i
RF
SERVO
HOLD
SP
MENU
OVER
OVER
40 30
20
10
0
dB
COUNTER
switch
Counter display
VCR Setup
Menu No. 516
DISPLAY SELECT
The counter display shows the following 4 types of information.
1.
Tape counter display
The counter display usually functions as a tape counter
(hour, minute, second, frame). It can be switched to a CTL
counter, time code or user's bit display by using the
COUNTER switch. (When the VCR Setup Menu item No.
516 DISPLAY SELECT is set to “TC”.)
CTL counter
: Time between -9 hr. 59 min. 59 sec. 29
frames and 9 hr. 59 min. 59 sec. 29 frames
can be displayed. Running mode is fixed as
non-drop frame.
* CTL counter indication may also corrupt
at playback of segment which time code
signal is not continuously recorded.
Time code
:
Time between 0 hour and 23 hr. 59 min. 59
sec. 29 frames can be displayed.
User's bit
:
Hexadecimal number from 0 to F is displayed
in 8 digits.
When the VCR Setup Menu item No. 516 DISPLAY SELECT
is set to “CLOCK”, the date and time are displayed. Set the
COUNTER switch to TC or UB.
TC: Time (Hour, Min., Sec.) is displayed.
UB: Date (Month, Day, Year) is displayed.
• Press the MENU button to switch to the VCR Setup Menu
setting display.
2.
VCR Setup Menu setting display
This display is used when setting the setup menus. After
setting of the setup menus, the tape counter display returns.
For details, see "DISPLAYING AND SETTING VCR SETUP
MENUS" on page 67.
3.
Hour meter display
The hour meter is displayed by selecting the HM group from
the VCR Setup Menu.
The hour meter data refers to the accumulated head drum
running time.
4.
Error code/Alarm display
The error code or alarm indicator is displayed automatically
in case an abnormal condition occurs with the unit.
See “TROUBLES WITH ERROR CODE OUTPUTS” on
page 90.
See “ALARM INDICATIONS” on page 86.
Remaining Battery Power Display
The 7-dot segment bar display shows the remaining battery
power. The lighted segment bars decrease as the remaining
battery power decreases.
To display the remaining battery power accurately, set the
VCR Setup Menu item No. 396
BATTERY TYPE according
to the type of the battery pack in use.
All segment bars light when a fully charged
battery pack is attached.
The last 2 segment bars and "BATT" start
to blink when the battery is nearly
exhausted. Replace with a fully charged
battery pack.
When the battery capacity has run out, "E"
and "BATT" blink and the unit stops
operation automatically.
VCR Setup Menu display
Error code display
Hour meter display
Alarm display
Tape counter display